Abstract:TiO2-graphene (TiO2-Gr) was coated on glassy carbon electrode (GCE) and hematoxylin was then electropolymerized on the modified electrode to fabricate an electrochemical sensor (polyhematoxylin/TiO2-graphene composite film modified glassy carbon electrode). The electrochemical behaviors of hydroquinone (HQ) on the modified electrode were investigated by cyclic voltammetry. The experimental results showed that the modified electrode had good electrocatalysis performance toward the redox of HQ. The oxidation peak current obviously improved compared to that on the bare GCE and TiO2-Gr/GCE. Differential pulse voltammetry was used for the determination of HQ. The concentration of HQ in the range of 3.0×10-6-1.0×10-3 mol/L showed good linear relationships with the oxidation peak current, with correlation coefficient (R) of 0.993. The detection limit was 1.0×10-7 mol/L (S/N=3). The developed method was used to determination of enviromental water samples with recoveries of 96.2% -105.6%.
卢先春 许春萱 王丹利 樊阳 黄克靖. 用聚苏木精/TiO2-石墨烯复合膜修饰玻碳电极差分脉冲伏安法测定水样中对苯二酚[J]. 冶金分析, 2012, 32(8): 13-19.
LU Xian-chun, WANG Dan-li, XU Chun-xuan. Determination of hydroquinone in water by differential pulse voltammetry with polyhematoxylin/TiO2graphene composite. , 2012, 32(8): 13-19.
[1] Ding Y, Liu W, Wu Q, et al. Direct simultaneous determination of dihydroxybenzene isomers at C-nanotube modified electrodes by derivative voltammetry [J]. Journal of Electroanalytical Chemistry, 2005, 575 (2): 275-280.
[2] Khalsf K D, Hasan B A, Morales R A. Spectrophotometric determination of phenol and resorcinol by reaction with p-aminophenol [J]. Talanta, 1994, 41 (4): 547-556.
[3] Larcher R, Nicolini G, Puecher C, et al. Determination of volatile phenols in wine using high-performance liquid chromatography with a coulometric array detector [J]. Anal. Chim. Acta, 2007, 582: 55-60.
[4] Martínez D, Pocurull E, Marcé R M, et al.Separation of eleven priority phenols by capillary zone electrophoresis with ultraviolet detection [J]. J.Chromatogr. A, 1996, 734: 367.
[5] Vanbeneden N, Delvaux E, Freddy R. Determination of hydroxycinnamic acids and volatile phenols in wort and beer by isocratic high-performance liquid chromatography using electrochemical detection [J]. J. Chromatogr. A, 2006, 1136 (2): 237-242.
[6] Shan C S, Yang H F, Song J F, et al.Direct electrochemistry of glucose oxidase and biosensing for glucose based on graphene [J]. Anal. Chem., 2009, 81(6): 2378-2382.
[7] Wang Y, Li Y M, Tang L H, et al. Application of graphene-modified electrode for selective detection of dopamine [J]. Electrochem. Commun., 2009, 11: 889-892.
[9] Xu S J, Liu Y, Wang T H, et al. Positive potential operation of a cathodic electrogenerated chemiluminescence immunosensor based on luminol and graphene for cancer biomarker detection [J]. Anal.Chem., 2011, 83 (10): 3817-3823.
[10] Luo Y, Tian Y, Zhu A, et al. Direct electron transfer of superoxide dismutase promoted by high conductive TiO2 nanoneedles [J]. Electrochem. Commun., 2009, 11 (1): 174~176.
[11] 熊小琴, 王兰, 张丽媛.TiO2-石墨烯修饰玻碳电极测定邻苯二酚[J]. 信阳师范学院学报 (Journal of Xinyang Normal University), 2011, 24( 4): 506-509.
[12] Zhang W D, Xu B, Jiang L C. Functional hybrid materials based on carbon nanotubes and metal oxides [J]. Journal of Materials Chemistry, 2010, 20: 6383-6392.
[13] Zhang H, Lu X, Li Y, et al. P25-graphene composite as a high performance photocatalyst [J]. ACS Nano, 2010, 4 (1): 380-386.
[14] Fan Y, Lu H T, Liu J H, et al. Hydrothermal preparation and electrochemical sensing properties of TiO2-graphene nanocomposite [J]. Colloids and Surfaces B: Biointerfaces, 2011, 83(1): 78-82.
[15] Hummers W S, Offeman R E. Preparation of graphitic oxide [J]. Journal of the American Chemistry Society, 1958, 80 (6): 1339-1339.
[16] Qi H, Zhang C. Simultaneous determination of hydroquinone and catechol at a glassy carbon electrode modified with multiwall carbon nanotubes [J]. Electroanalysis, 2005, 17(10): 832-838.
[17] Wang L, Huang P, Bai J, et al. Covalent modification of a glassy carbon electrode with penicillamine for simultaneous determination of hydroquinone and catechol [J]. Microchim. Acta, 2007, 158(1-2): 151-157.
[18] Zhao D, Zhang X, Feng L, et al. Simultaneous determination of hydroquinone and catechol at PASA/MWNTs composite film modified glassy carbon electrode [J]. Colloids and Surfaces B: Biointerfaces, 2009, 74(1): 317-321.
[19] Yang P, Zhu Q, Chen Y, et al. Simultaneous determination of hydroquinone and catechol using poly(p-aminobenzoic acid) modified glassy carbon electrode [J]. Journal of Applied Polymer science, 2009, 113(5): 2881-2886.
[20] Ahammad A, Sarker S, Rahman M, et al. Simultaneous determination of hydroquinone and catechol at an activated glassy carbon electrode [J]. Electroanalysis, 2010, 22(2): 694-700.