提出了以灼烧法和HNO3-HClO4法分别处理树脂,采用火焰原子吸收光谱法(FAAS)测定试样中金的方法。研究了称样量、灰化温度和测定介质对测定的影响,确定了最佳实验条件;讨论了共存离子的干扰。结果表明,金浓度在0.5~20 μg/mL范围内与吸光度呈良好的线性关系,线性相关系数为0.999 3,方法检出限分别为 0.17、0.19 μg/mL。分别采用两种方法对实际样品进行测定,结果与火试金-重量法一致,相对标准偏差(n=11)分别为1.5%与1.6%,加标回收率分别为97%~101%、98%~102%。
Abstract
A determination method of gold in resin by flame atomic asorption spectrometry was proposed after the sample was pretreated by ignition and HNO3-HClO4 method. The effect of sample weight, ashing temperature and determination medium on determination was investigated to obtain optimal experimental conditions. The interference of coexisting ions was discussed. It was found that, gold concentration in range of 0.5-20 μg/mL exhibited good linearity to absorbance. The linear correlation coefficient was 0.999 3. Detection limits of this two method were 0.17 and 0.19 μg/mL, respectively. Two methods were applied to the determination of actual samples, and the results were consistent with those obtained by fire assaying-gravimetry. The relative standard deviation (RSD, n=11) was 1.5 % and 1.6%, respectively. The recoveries were 97%-101% and 98%-102%, respectively.
关键词
火焰原子吸收光谱法 /
金 /
树脂 /
灼烧法 /
HNO3-HClO4法
{{custom_keyword}} /
Key words
flame atomic absorption spectrometry /
gold /
resin /
ignition method /
nitric acid-perchloric acid method
{{custom_keyword}} /
中图分类号:
O657.31
{{custom_clc.code}}
({{custom_clc.text}})
{{custom_sec.title}}
{{custom_sec.title}}
{{custom_sec.content}}
参考文献
[1] 王永录, 刘正华. 金、银及铂族金属的再生回收[M]. 长沙: 中南大学出版社, 2005.
[2] 李小玲. 火试金法测定树脂中的金[J]. 黄金(Gold), 2010, 31(4): 54-55.
[3] GB/T 15072.1-2008 贵金属合金化学分析方法 金、铂、钯合金中金量的测定 硫酸亚铁电位滴定法[S].
[4] 张利, 朱化雨, 宋兴良. 极谱络合吸附波测定痕量金的研究[J]. 理化检验-化学分册(Physical Testing and Chemical Analysis Part B: Chemical Analysis). 2005, 41(10): 748-750.
[5] Alaa S Amin. Utility of solid phase extraction for spectrophotometric determination of gold in water, jewel and ore samples[J]. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2010, 77(5): 1054-1058.
[6] Liang Pei, Zhao Ehong, Ding Qiong, et al. Multiwalled carbon nanotubes microcolumn preconcentration and determination of gold in geological and water samples by flame atomic absorption spectrometry[J]. Spectrochimica Acta Part B: Atomic Spectroscopy, 2008, 63(6): 714-717.
[7] Liu Rui, Liang Pei. Determination of gold by nanometer titanium dioxide immobilized on silica gel packed microcolumn and flame atomic absorption spectrometry in geological and water samples[J]. Analytica Chimica Acta, 2007, 604(2):114-118.
[8] 胡力玫, 郑红, 刘江涛, 等. 改性纳米二氧化钛分离富集电感耦合等离子体原子发射光谱法测定地质样品中金钯铑[J]. 冶金分析(Metallurgical Analysis), 2012, 32(2): 38-41.
[9] 吴奕阳, 叶晓珉, 方名戊. 波长色散X射线荧光光谱法测定纯金中金[J]. 理化检验-化学分册(Physical Testing and Chemical Analysis Part B: Chemical Analysis), 2003, 39(11): 639-641.
{{custom_fnGroup.title_cn}}
脚注