Abstract:The contents of oxygen, nitrogen and hydrogen in iron and steel were simultaneously determined by pulse melting―time-of-flight mass spectrometry. By comparing the mass spectrogram of blank and sample, C+, N+ and H2+, were used as the analytical lines of mass spectrum. The oxygen, nitrogen and hydrogen in a series of standard samples were determined. The calibration curve was plotted based on the ionic number of analytical lines and mass of elements. According to the standard deviation of blank, the detection limits of oxygen, nitrogen and hydrogen were 0.000 015%, 0.000 02% and 0.000 003%, respectively. The proposed method was applied to the determination of standard sample, and the results were consistent with the certified values. The relative standard deviations (RSD) were 1.4 %-7.4 %. In this method, the mass spectrum detector was used in the simultaneous and quantitative analysis of oxygen, nitrogen and hydrogen in steel materials. The allowable error of determination results could meet the requirements of national standard and the analysis of gases in steel materials.
胡少成*,沈学静,王蓬,郝贵奇,马红权,胡学强,王海舟. 脉冲熔融-飞行时间质谱法同时测定钢铁中氧、氮和氢[J]. 冶金分析, 2011, 31(7): 26-30.