Abstract:In order to solve the problem of large error during the determination of copper content in copper and copper alloys by energy dispersive X-ray fluorescence spectroscopy (EDXRF), the sample was pretreated by acid decomposition in experiments. The copper standard solution series were prepared with standard solution. The calibration curve was drawn with the mass concentration of copper as the abscissa and the fluorescence intensity as the ordinate. A method for the determination of copper in copper and copper alloys by EDXRF after acid digestion was established. The effects of wetting water consumption, hydrochloric acid dosage, nitric acid dosage and post-reaction treatment on the determination were investigated by orthogonal tests, and the optimal acid digestion conditions were obtained. The contents of copper in four copper and copper alloy CRMs were determined according to the experimental method. The relative standard deviations (RSD, n=13) of determination results were between 0.32% and 0.68%. The measured values were weill consistent with the certified values. The contents of copper in four copper products were determined according to the experimental method and GB/T 5121.1-2008, and it was found that the test results were consistent. The proposed method could well overcome the matrix effect and solve the matching problem of solid standard sample. This method could meet the requirements of daily inspection.
刘志英, 李明茂, 刘奇, 王丽丽, 章新亮, 袁江山. 酸消解-能量色散X射线荧光光谱法测定铜及铜合金中铜[J]. 冶金分析, 2023, 43(11): 39-44.
LIU Zhiying, LI Mingmao, LIU Qi, WANG Lili, ZHANG Xinliang, YUAN Jiangshan. Determination of copper in copper and copper alloy by acid digestion and energy dispersive X-ray fluorescence spectrometry. , 2023, 43(11): 39-44.
[1] 陈召.能量色散X射线荧光光谱分析技术研究[D].兰州:西北师范大学,2022. [2] 李庆波,毕智棋,石冬冬.基于能量色散X射线荧光光谱的鱼粉产地溯源方法研究[J].光谱学与光谱分析,2021,41(3):745-749. LI Qingbo,BI Zhiqi,SHI Dongdong.The method of fishmeal origin tracing based on EDXRF spectrometry analysis[J].Spectroscopy and Spectral Analysis,2021,41(3):745-749. [3] 赵修平,高婧怡,王宗义,等.能量色散X射线荧光光谱快速检测食盐中的碘[J].北京农学院学报,2022,37(4):118-120. ZHAO Xiuping,GAO Jingyi,WANG Zongyi,et al.Rapid determination of iodine in edible salt by energy dispersive X-ray fluorescence spectrometry[J].Journal of Beijing University of Agriculture,2022,37(4):118-120. [4] 石洪玮,刘晓静,刘贵巧,等.单波长激发-能量色散X射线荧光光谱法检测蔬菜中多种重金属元素[J].中国无机分析化学,2022,12(4):1-8. SHI Hongwei,LIU Xiaojing,LIU Guiqiao,et al.Determination of heavy metals in vegetables by single wavelength excitation-energy dispersive X-ray fluorescence spectrometry[J].Chinese Journal of Inorganic Analytical Chemistry,2022,12(4):1-8. [5] 王蕾越,战可涛,尹亮.基于新型滤波准直器的土壤重金属EDXRF检测方法[J].北京化工大学学报(自然科学版),2021,48(4):111-118. WANG Leiyue,ZHAN Ketao,YIN Liang.An EDXRF detection method of heavy metals in soil based on new filter collimator[J].Journal of Beijing University of Chemical Technology(Natural Science Edition),2021,48(4):111-118. [6] 程大伟,倪子月,廖学亮,等.能量色散X射线荧光光谱法测定自来水中痕量氯[J].冶金分析,2019,39(5):37-40. CHENG Dawei,NI Ziyue,LIAO Xueliang,et al.Determination of trace chlorine in tap water by energy dispersive X-ray fluorescence spectrometry[J].Metallurgical Analysis,2019,39(5):37-40. [7] 刘敏. EDXRF中FP法无标样分析技术的优化研究及应用[D].成都:成都理工大学,2013. [8] 蒯丽君,樊兴涛,詹秀春,等.酸消解-车载偏振能量色散X射线荧光法现场测定祁曼塔格多金属矿中高品位铜铅锌[J].岩矿测试,2013,32(4):538-546. KUAI Lijun,FAN Xingtao,ZHAN Xiuchun,et al.On-site Analysis of Cu,Pb and Zn in polymetallic ores from qimantage area by vehicle-loaded polarized energy dispersive X-ray fluorescence spectrometer with acid digestion[J].Rock and Mineral Analysis,2013,32(4):538-546. [9] 蒯丽君,詹秀春,樊兴涛,等.偏振能量色散X射线荧光光谱法测定硫化物矿石中的铜铅锌[J].岩矿测试,2013,32(6):903-908. KUAl Lijun,ZHAN Xiuchun,FAN Xingtao,et al.Determination of Cu,Pb and Zn in sulfide ores by polarized energy dispersive X-ray fluorescence spectrometry[J].Rock and Mineral Analysis,2013,32(6):903-908. [10] 吉昂,卓尚军,李国会.能量色散X射线荧光光谱[M].北京:科学出版社,2017:331-332. [11] 何一芳,王立新,蒋月娟,等.微波消解-ICP-AES法同时测定铜铬锆合金中的铬、锆[J].中国测试,2014,40(5):52-54. HE Yifang,WANG Lixin,JIANG Yuejuan,et al.Simultaneous determination of chromium and zirconium in Cu-Cr-Zr alloy by microwavedigestion-ICP-AES[J].China Measurement & Test,2014,40(5):52-54. [12] 郝璐,冯振华.碘量法测定铜铅合金中铜的方法改进[J].冶金分析,2022,42(10):77-82. HAO Lu,FENG Zhenhua.Method improvement for the determination of copper in copper-lead alloy by iodometry[J].Metallurgical Analysis,2022,42(10):77-82. [13] 马丽君.火焰原子吸收光谱法测定粗铜中痕量铋、锑[J].理化检验(化学分册),2010,46(1):36-37,40. MA Lijun.FAAS determination trace amounts of bismuthand antimony in crude copper[J].Physical Testing and Chemical Analysis(PartB:Chemical Analysis),2010,46(1):36-37,40. [14] 张江坤,冯晓军,叶罕章,等.微波消解滤纸制样XRF法测定磷矿石中的多元素[J].磷肥与复肥,2013,28(4):74-75. ZHANG Jiangkun,FENG Xiaojun,YE Hanzhang,et al.Determination of multi elements in phosphate rock with microwave digestion andfilter paper sample preparation by XRF method[J].Phosphate & Compound Fertilizer,2013,28(4):74-75. [15] 国家市场监督管理总局,国家标准化管理委员会. GB/T 5231.1—2022加工铜及铜合金牌号和化学成分[S].北京:中国标准出版社,2022. [16] 贾云海,孙晓飞,张帆.用相对标准偏差和相对极差及测量极值比例确定分析检出限和定量限[J].冶金分析,2021,41(1):1-12. JIA Yunhai,SUN Xiaofei,ZHANG Fan.Determination of LOD and LOQ with relative standard deviation and relative range or ratio of maximum and minimum[J].Metallurgical Analysis,2021,41(1):1-12.