Abstract:High-purity gold targets are widely used in electronic and information industry. The content of impurity elements in target products has high requirements. The use performance of high-purity gold target products will be affected if the content of impurity elements is on the high side. The experimental conditions of glow discharge mass spectrometry (GDMS), including the discharge current, the flow rate of discharge gas (argon) and the pre-sputtering time of sample, were optimized. The measuring isotopes were selected according to the principle of high abundance, with no or little interference. Meanwhile, the possible MS interference was overcome by selecting the resolution. The analysis method of 42 impurity elements in high-purity gold target by GDMS was established. The contents of 42 impurity elements in high-purity gold target sample were determined according to the experimental method. The results showed that the relative standard deviations (RSD) for impurities with mass fraction higher than 100 μg/kg were all less than 10%, and the RSDs for other testing elements were basically less than 46%. Due to the lack of certified reference materials of high-purity gold, the elements with relatively high content (such as Ca, Fe, Pd, Ag, Pt, Cr, Cu and Ni) were also determined by inductively coupled plasma mass spectrometry (ICP-MS) for comparison. The determination results of experimental method were in good agreement with those obtained by inductively coupled plasma mass spectrometry(ICP-MS).
王长华, 王伟华, 墨淑敏, 胡芳菲, 李娜. 辉光放电质谱法测定高纯金靶材中42种杂质元素[J]. 冶金分析, 2021, 41(2): 9-15.
WANG Changhua, WANG Weihua, MO Shumin, HU Fangfei, LI Na. Determination of forty-two impurity elements in high-purity gold target by glow discharge mass spectrometry. , 2021, 41(2): 9-15.
徐剑瑛.电感耦合等离子体质谱法测定高纯金中杂质元素[J].广东化工,2019,46(20):113-115,125.XU Jianying.Determination of impurity elements in high purity gold by inductively coupled plasma mass spectrometry[J].Guangdong Journal of Chemical Engineering,2019,46(20):113-115,125.
[7]
苏菁,刘孟刚.全谱直读等离子体发射光谱法测定高纯金中的杂质元素[J].岩矿测试,2004(4):300-302.SU Jing,LIU Menggang.Impurity determination in high purity golden materials by inductively coupled plasma optical emission spectroscopy[J].Rock and Mineral Analysis, 2004(4):300-302.
李继东,王长华,郑永章.铝合金中微量元素辉光放电质谱定量分析研究[J].质谱学报,2012,33(1):18-22.LI Jidong,WANG Changhua,ZHENG Yongzhang.The quantitative analysis for microelement content in alumina by glow discharge mass spectrometry. journal of chinese mass spectrometry society quantitative[J].2012,33(1):18-22.
[10]
刘元元,胡净宇.辉光放电质谱法测定棒状高纯镁中12种杂质元素[J].冶金分析,2018,38(4):16-21.LIU Yuanyuan,HU Jingyu.Determination of twelve elements in rodlike high purity magnesium by glow discharge mass spectrometry[J].Metallurgical Analysis,2018,38(4): 16-21.
[11]
王爽,白杉,徐平,等.辉光放电质谱法在高纯材料分析中的应用[J].中国无机分析化学,2019,9(2):24-34.WANG Shuang,BAI Shan,XU Ping,et al.Application of GDMS for the analysis of high purity materials[J].Chinese Journal of Inorganic Analytical Chemistry,2019,9(2):24-34.
[12]
杨海岸,罗舜,闫豫昕,等.辉光放电质谱法测定高纯镍中16种痕量杂质元素[J].冶金分析,2015,35(5):1-6.YANG Haian,LUO Shun,YAN Yuxin,et al.Determination of sixteen trace impurity elements in high-purity nickel by glow discharge mass spectrometry[J].Metallurgical Analysis,2015,35(5):1-6.
[13]
李爱嫦,刘红,李继东,等.辉光放电质谱法测定高纯铝中杂质元素[J].分析试验室,2015,34(4):480-483.LI Aichang,LIU Hong,LI Jidong,et al.Determination of impurities in high aluminium by glow discharge mass spectrometry[J].Chinese Journal of Analytical Chemistry,2015,34(4):480-483.
[14]
贾云海,孙晓飞,张帆.用相对标准偏差和相对极差及测量极值比例确定分析检出限和定量限[J].冶金分析,2021,41(1):1-12.JIA Yunhai,SUN Xiaofei,ZHANG Fan. Determination of LOD and LOQ with relative standard deviation and relative range or ratio of maximum and minimum[J]. Metallurgical Analysis,2021,41(1):1-12.