Abstract:During the determination of lead and cadmium in soil sample by graphite furnace atomic absorption spectrometry, the results cannot meet the requirements of quality control sometimes if it is operated directly according to the standard GB/T 17141-1997. The results showed that the slope of calibration curve was significantly different when the standard solution series of target elements contained or did not contain the mixed elements of soil matrix elements including Na, Mg, Al, Si, Fe and Ca. In order to reduce the influence of matrix effect, the procedures in standard method above were improved based on literatures and experiments as follows: (1) the digestion solution of actual sample with same volume was mixed and then quantitatively added into the standard solution series for preparation of calibration curves for matrix matching; (2) the digestion solution was diluted appropriately and the calibration curves were still established with the standard solutions. The improved method was verified using four soil standard samples and spiked results of soil sample. The results showed that the recovery range of Pb in matrix dilution method was 90.4%-114%. For the low content of Cd, the recovery range was 84.1%-125%. The recovery range of Pb and Cd in matrix matching method was 93.0%-105% and 102%-119%, respectively, which could basically meet the quality control requirements of recovery for heavy metals in soil sample, i.e., 80%-120%. When the content of trace cadmium in sample was near the lower determination limit, the dilution factor should be strictly controlled or the sample should be determined by matrix matching method. The modified operation procedures in this study were suitable for the accurate determination of Pb and Cd in large batches of soil samples in routing inspection.
乔娜, 包毓含, 杨丽, 刘桂青, 郭超, 范爽. 基体稀释或基体匹配石墨炉原子吸收光谱法测定土壤样品中铅和镉[J]. 冶金分析, 2019, 39(11): 9-15.
QIAO Na, BAO Yu-han, YANG Li, LIU Gui-qing, GUO Chao, FAN Shuang. Determination of lead and cadmium in soil samples by graphite furnace atomic absorption spectrometry based on matrix dilution or matrix matching. , 2019, 39(11): 9-15.
张红医,刘梦垚,李美婷,等.不同于教科书中的标准加入法——开放环境下授课的实例[J].化学教育,2018,39(24):71-77.ZHANG Hong-yi,LIU Meng-yao,LI Mei-ting,et al.Standard addition methods different from description in textbooks:a case for teaching in open environment[J].Chemistry Education,2018,39(24):71-77.
[4]
房超,周薇,宋薇.湿法消解-石墨炉原子吸收标准加入法测定土壤中的镉[J].化学计量分析,2015,24(1):74-76.FANG Chao,ZHOU Wei,SONG Wei.Determination of cadmium in soil by mixed acid digestion and graphite furnace atomic absorption spectrometry standard addition method[J].Chemical Analysis and Meterage,2015,24(1):74-76.
[5]
刘英波,李超,杨璠,等.石墨炉原子吸收光谱法测定土壤中的痕量镉[J].云南冶金,2018,47(5):64-67,72.LIU Ying-bo,LI Chao,YANG Fan,et al.Determination on trace cadmium in soil by graphite furnace atomic absorption spectrometry[J].Yunnan Metallurgy,2018,47(5):64-67,72.
[6]
姜晴,刘嫣.电感耦合等离子体质谱法测定纯铟中镁铬锰钴镍锆钼锑[J].冶金分析,2017,37(6):65-68.JIANG Qing,LIU Yan.Determination of Mg,Cr,Mn,Co,Ni,Zr,Mo,Sb in pure indium by ICP-MS[J].Metallurgical Analysis,2017,37(6):65-68.
[7]
陈丰.土壤中重金属监测分析方法讲解[C]∥第二届中国国际土壤与地下水修复高峰论暨土壤与地下水监测技术分论坛会议论文集.上海:Soiltec China 2017暨土壤与地下水监测技术论坛组委会,2017.
[8]
赵志南.土壤重金属常规分析技术要点[C]∥第三届中国国际土壤与地下水修复高峰论暨土壤与地下水监测技术分论坛会议论文集.上海:Soiltec China 2018暨土壤与地下水监测技术论坛组委会,2018:189.
邓勃.仪器定量分析中几个问题的探讨[J].中国无机分析化学,2011,1(2):1-5.DENG Bo.The discussion of some problems in quantitative instrumental analysis[J].Chinese Journal of Inorganic Analytical Chenistry,2011,1(2):1-5.