Determination of aluminum oxide, magnesium oxide and silicon oxide in alumina-magnesia spinel by energy dispersive X-ray fluorescence spectrometry with fusion sample preparation
HU Zheng-yang, LUO Qi-sheng, ZHANG Song-lin, WANG De-jun
R & D Institute of Raitai-Masteel New Material Technology Co., Ltd., Maanshan 243000, China
Abstract:The analysis of alumina-magnesia spinel in standards mainly adopted wet method or wavelength dispersion X-ray fluorescence spectrometry. With the rapid development of energy dispersive X-ray fluorescence spectrometer (EDXRF), it has been widely used for the elemental analysis in many industries. A determination method of Al2O3, MgO and SiO2 in alumina-magnesia spinel by EDXRF with fusion sample preparation was established. Since there were no ready-made certified reference materials (CRMs) of alumina-magnesia spinel, proper CRMs such as special bauxite and high-purity magnesia were selected in experiments. Meanwhile, a series of calibration samples were synthesized with special bauxite CRM and high-purity magnesia CRM, as well as aluminum oxide primary standard and high purity magnesia CRM according to the production process of alumina-magnesia spinel. When the sample mass as was fixed at 0.5000g, the dilution ratio of sample to anhydrous lithium tetraborate (Li2B4O7) flux was 1∶16, and four drops of 0.5g/mL NH4Br solution was used as the releasing reagent, the melting effect of sample was good at 1150℃. The calibration curves were prepared with the selected CRMs and calibration sample. The root-mean-square (RMS) of calibration curves for Al2O3, MgO and SiO2 were 0.916, 0.888 and 0.029, respectively. The precision test was conducted with the CRMs of magnesia-alumina brick. The relative standard deviation (RSD, n=5) of determination results for Al2O3, MgO and SiO2 were 1.4%, 0.42% and 3.1%, respectively. The CRMs of magnesia-alumina brick and alumina-magnesia refractory as well as alumina-magnesia spinel actual sample were analyzed according to the experimental method. The results of Al2O3, MgO and SiO2 were basically consistent with the certified values or those obtained by the wet method. The proposed method could meet the requirements of production inspection.
胡正阳, 罗齐圣, 张松林, 王德军. 熔融制样-能量色散X射线荧光光谱法测定铝镁尖晶石中氧化铝、氧化镁和氧化硅[J]. 冶金分析, 2019, 39(3): 33-37.
HU Zheng-yang, LUO Qi-sheng, ZHANG Song-lin, WANG De-jun. Determination of aluminum oxide, magnesium oxide and silicon oxide in alumina-magnesia spinel by energy dispersive X-ray fluorescence spectrometry with fusion sample preparation. , 2019, 39(3): 33-37.
卫战业,程爱团.铝镁尖晶石炭钢包砖的研制[J].耐火材料,2000,34(6):342-343.WEI Zhan-ye,CHENG Ai-tuan.Preparation of Al2O3-MgO spinel carbon brick for ladle[J].Refractories,2000,34(6):342-343.
[2]
朱新军.连铸钢包用铝镁尖晶石-炭砖的研制及应用[J].耐火材料,2000,34(2):100-102.ZHU Xin-jun.Development and application of MA spinel-C brick for continuous casting ladle[J].Refractories,2000,34(2):100-102.
[3]
陶绍平,曹勇.铝镁尖晶石炭砖在盛钢桶上的应用[J].耐火材料,1994,28(3):165-166,169.TAO Shao-ping,CAO Yong.Application of alumina-magnesia spinel brick in ladle[J].Refractories,1994,28(3):165-166,169.
[4]
曲月华,王翠艳.X-射线荧光光谱法测定铝质耐火材料中主次成分[J].冶金分析,2006,26(4):36-39.QU Yue-hua,WANG Cui-yan.Determination of major and minor components in aluminum refractory by X-ray fluorescence spectrometry[J].Metallurgical Analysis,2006,26(4):36-39.
[5]
唐红霞,付宝荣.X射线荧光光谱法测定镁质耐火材料中多元素[J].甘肃冶金,2011,33(6):91-93.TANG Hong-xia,FU Bao-rong.Determination of multi-elements in magnesite based refractory materials using X-ray fluorescence spectrometer[J].Gansu Metallurgy,2011,33(6):91-93.
[6]
王芙云,袁翠菊,任向阳.X射线荧光光谱法快速分析镁质耐火材料中硅铝铁钛钙镁[J].岩矿测试,2008,27(3):232-234.WANG Fu-yun,YUAN Cui-ju,REN Xiang-yang.Rapid determination of SiO2,Al2O3,Fe2O3,TiO2,CaO and MgO in magnesium-based refractory materials by X-ray fluorescence spectrometry with powder pellet sample preparation[J].Rock and Mineral Analysis,2008,27(3):232-234.
[7]
李强,黄万燕,王勇刚,等.能量色散X射线荧光光谱法测量钢铁中的铅[J].冶金分析,2012,32(7):41-44.LI Qiang,HUANG Wan-yan,WANG Yong-gang,et al.Determination of lead in iron and steel by energy dispersive X-ray fluorescence spectrometry[J].Metallurgical Analysis,2012,32(7):41-44.
[8]
罗建林.能量色散X射线荧光光谱法在测定油品硫含量中的应用[J].分析仪器,2003(3):31-34.LUO Jian-lin.Determination of sulphur in petroleum by energy dispersive X-ray fluorescence spectrometry[J].Analytical Instrumentation,2003(3):31-34.
[9]
王冬圻,姜瞻梅,田然,等.能量色散X射线荧光光谱法测定奶粉中钙元素[J].食品科学,2013,34(24):254-257.WANG Dong-qi,JIANG Zhan-mei,TIAN Ran,et al.Determination of calcium in milk power by energy dispersive X-ray fluorescence spectrometry[J].Food Science,2013,34(24):254-257.