Determination of platinum in Oleflex catalyst by inductively coupled plasma mass spectrometry
ZHONG Sheng-hui1,2, CHENG Nan-nan1, WANG Hong-ying3, YAN Wei-shan1
1. Oriental Energy (Ningbo) New Material Co., Ltd., Ningbo 315812, China; 2. School of Petrochemical Engineering, Changzhou University, Changzhou 213164, China; 3. Oriental Energy Co., Ltd., Nanjing 210042, China;
Abstract:Oleflex process has been paid more and more attention. The platinum content in Oleflex catalyst has a great influence on the activity of catalyst. Therefore, it is necessary to develop a high-efficiency and stable method for the determination of platinum. The catalyst sample was dissolved with aqua regia. The standard solutions for the preparation of calibration curve were treated by the matching of Al matrix to eliminate the matrix effect. 195Pt was selected as the isotope to establish the determination method of platinum in Oleflex catalyst by inductively coupled plasma mass spectrometry (ICP-MS). The carrier gas flow and determination medium were optimized: the carrier gas flow was 10.5L/min and the medium was 2% HCl (V/V). The effect of matrix Al on the determination of platinum was investigated. It was found that the negative effect was significant. The content of Al in the sample solution was determined by ICP-MS. The results showed that the mass ratio of dissolved Al2O3 in catalyst was about 19% regardless the sampling amount was 0.1g or 0.2g. Therefore, 0.1g of sample was used in experiments. The matrix matching method was adopted to make sure that the mass concentration of Al in standard solution series for calibration curve was all 40μg/mL, thus eliminating the matrix effect. The standard solution series of Pt were determined under the selected experimental conditions. The calibration curve was prepared using the mass concentration of Pt as the horizontal coordinate and the corresponding analysis signal intensity as the vertical coordinate. The linear range of method was 0.001-2.00μg/mL, the linear correlation coefficient was 0.9999, and the detection limit was 0.0004μg/mL. The content of platinum in fresh Oleflex catalyst, regenerated Oleflex catalyst and waste Oleflex catalyst samples were determined according to the experimental method. The relative standard deviations (RSD, n=5) of measured results ranged from 1.5% to 2.8%. The spiked recoveries were between 97% and 104%. The content of platinum in three catalysts above was determined by the experimental method and standard method GB/T 23524-2009, respectively. The determination results were verified by t test. The results showed that there was no significant difference between two methods for the determination of platinum content in catalyst samples.
韩香莲.丙烯生产工艺研究进展[J].山东化工,2013,42(5):60-62.HAN Xiang-lian.Development of propylene production technology[J].Shangdong Chemical Industry,2013,42(5):60-62.
[2]
陈硕,王定博,吉媛媛,等.丙烯为目的产物的技术进展[J].石油化工,2011,40(2):217-224.CHEN Shuo,WANG Ding-bo,JI Yuan-yuan,et al.Development in on-purpose propylene technology[J].Petrochemical Technology,2011,40(2):217-224.
[3]
曹秋娥,李祖碧,王加林,等.铂族金属催化动力学光度分析法[J].冶金分析,2002,22(3):29-37.CAO Qiu-e,LI Zu-bi,WANG Jia-lin,et al.Catalytic kinetic spectrophotometric methods for the determination of platinum group metals[J].Metallurgical Analysis,2002,22(3):29-37.
[4]
刘锡林,李琼,张宏,等.二溴硝基偶氮氯膦催化动力学光度法测定微量铂(IV)、铑(III)的研究[J].兰州文理学院学报:自然科学版,2005,19(4):38-40.LIU Xi-lin,LI Qiong,ZHANG Hong,et al.Catalytic spectrophotometric determination of trace platinum and rhodium with periodate-dibromo-nitro-chlorophsphonazo system[J].Journal of Gansu Lianhe University: Natural Sciences,2005,19(4):38-40.
[5]
丁宗庆,刘光东,吕丽丽.溴酸钾-溴甲酚紫催化动力学光度法测定痕量铂[J].冶金分析,2008,28(9):77-79.DING Zong-qing,LIU Guang-dong,L Li-li.Catalytic kinetic spectrophotometric determination for trace platinum with potassium bromate and bromocresol purple system[J].Metallurgical Analysis,2008,28(9):77-79.
[6]
朱若华,邹洪,贺闰娟.贵金属元素铂、铑、钯的分析进展[J].分析试验室,2004,23(2):82-92.ZHU Ruo-hua,ZOU Hong,HE Run-juan.Development of methods for determination of Pt, Pd and Rh[J].Chinese Journal of Analysis Laboratory,2004,23(2):82-92.
[7]
魏秀萍,李倩.分光光度法测定CO助燃剂中铂含量[J].分析测试技术与仪器,2013,19(4):214-216.WEI Xiu-ping,LI Qian.Spectrophotometic determination of platinum in CO combustion improver[J].Analysis and Testing Technology and Instruments,2013,19(4):214-216.
[8]
霍燕燕.2-(5-碘-2-吡啶偶氮)-5-二甲氨基苯胺分光光度法测定催化剂中的铂[J].光谱实验室,2013,30(3):1501-1504.HUO Yan-yan.Spectrophotometric determination of platinum (IV) in catalyst with 2-(5-iodine-2-pyridylazo)-5-dimethylaminoaniline[J].Chinese Journal of Spectroscopy Laboratory,2013,30(3):1501-1504.
[9]
王敏,凌凤香.Pt/SiO2-Al2O3催化剂中铂含量测定的方法[J].理化检验:化学分册,2008,44(1):17-18.WANG Min,LING Feng-xiang.Determination of platinum in Pt/SiO2-Al2O3 catalyst[J].Physical Testing and Chemical Analysis Part B:Chemical Analysis,2008,44(1):17-18.
[10]
施意华,王晟,杨仲平,等.火焰原子吸收光谱法测定尾气净化金属载体催化剂中铂钯铑[J].冶金分析,2012,32(3):14-19.SHI Yi-hua,WANG Sheng,YANG Zhong-ping,et al.Determination of platinum, palladium, rhodium in metal carrier catalyst for exhaust gas purification by flame atomic absorption spectrometry[J].Metallurgical Analysis,2012,32(3):14-19.
[11]
谭文进,郑允,贺小塘,等.碱熔-碲共沉淀富集-电感耦合等离子体原子发射光谱法测定石油化工废催化剂不溶渣中铂钯[J].冶金分析,2016, 36(2):43-48.TAN Wen-jin,ZHENG Yun,HE Xiao-tang,et al.Determination of platinum and palladium in insoluble slag of waste catalyst for petrochemical industry by inductively coupled plasma atomic emission spectrometry after alkali fusion-tellurium coprecipitation enrichment[J].Metallurgical Analysis,2016,36(2):43-48.
[12]
朱茜,邓飞跃,彭穗,等.真空蒸馏预富集-电感耦合等离子体发射光谱法测定铂[J].分析化学,2010,38(6):889-892.ZHU Xi,DENG Fei-yue,PENG Sui,et al.Vacuum distillation separation/enrichment and inductively coupled plasma-atomic emission spectrometry for determination of platinum[J].Chinese Journal of Analytical Chemistry,2010,38(6):889-892.
[13]
刘英,臧慕文.ICP-AES测定废Al2O3基催化剂中Pt、Pd[J].分析试验室,2002(6):40-43.LIU Ying, ZANG Mu-wen.Determination of Pt and Pd in spent Al2O3 catalyst by ICP-AES[J].Chinese Journal of Analysis Laboratory,2002(6):40-43.
[14]
靳兰兰,王秀季,李会来,等.电感耦合等离子体质谱技术进展及其在冶金分析中的应用[J].冶金分析,2016,36(7):1-14.JIN Lan-lan,WANG Xiu-ji,LI Hui-lai,et al.Progress in inductively coupled plasma mass spectrometry technology and its application in metallurgical analysis[J].Metallurgical Analysis,2016,36(7):1-14.
[15]
田衎,孙自杰,周裕敏,等.电感耦合等离子体质谱法分析高纯金属银中痕量杂质元素[J].冶金分析,2016,36(7):51-55.TIAN Kan,SUN Zi-jie,ZHOU Yu-min,et al.Determination of trace impurity elements in high purity metal silver by inductively coupled plasma mass spectrometry[J].Metallurgical Analysis,2016,36(7):51-55.