Determination of aluminum,calcium,barium,manganese and zirconium in silicon-manganese-zirconium inoculant by inductively coupled plasma atomic emission spectrometry
ZUO Liang
The North China Mineral and Geology Testing Center of CNNC,Tianjin 300181,China
Abstract:The sample was decomposed with nitric acid-hydrofluoric acid-hydrochloric acid. After removing silicon and fluorine by perchloric acid smoking, the salts were finally dissolved with hydrochloric acid. Al 396.152 nm, Ca 315.887 nm, Ba 233.527 nm, Mn 257.610 nm and Zr 339.197 nm were selected as analytical lines to determine aluminum, calcium, barium, manganese and zirconium in silicon-manganese-zirconium inoculant by inductively coupled plasma atomic emission spectrometry (ICP-AES). The influence of matrix effect and spectral interference on determination caused by coexisting ion irons was reduced and avoided via sample solution dilution. The mass concentration of aluminum, calcium, barium, manganese and zirconium in range of 0.50-4.00 μg/mL was linear to its corresponding emission intensity. The linear correlation coefficients of calibration curves were higher than 0.999 9. The detection limit of aluminum, calcium, barium, manganese and zirconium was between 0.60 μg/g and 1.1 μg/g. The relative standard deviations (RSD, n=10) of determination results for aluminum, calcium, barium, manganese and zirconium in silicon-manganese-zirconium inoculant according to experimental method were between 1.6% and 3.0%. The results were consistent with those obtained by other methods.
张文和,丁俊,聂富荣.几种孕育剂简介[J].现代铸铁,2007,27(4):71-73.ZHANG Wen-he,DING Jun,NIE Fu-rong.A brief introduction to some inoculants[J].Modern Cast Iron,2007,27(4):71-73.
[2]
王峰,王快社,马林生,等.核级锆及锆合金研究状况及发展前景[J].兵器材料科学与工程,2012,35(1):107-110.WANG Feng,WANG Kuai-she,MA Lin-sheng,et al.Current situation and development trend of zirconium and zirconium alloys[J].Ordnance Material Science and Engineering,2012,35(1):107-110.
[3]
刘鹏,杜忠泽,马林生,等.核级锆及锆合金腐蚀性能研究现状[J].热加工工艺,2011,40(22):22-24.LIU Peng,DU Zhong-ze,MA Lin-sheng,et al.Study status of corrosion properties of zirconium and zircaloy in reactor[J].Hot Working Technology,2011,40(22):22-24.
[4]
V M Grigor’ev.Zirconium alloys produced from far eastern minerals[J].Steel in Translation,2011,41(2):130-134.
焦风菊,郭英英.硅钡孕育剂中钙、钡的测定[J].铸造技术,2011(8):1187-1188.JIAO Feng-ju,GUO Ying-ying.Determination of barium and calcium in Si-Ba inoculant[J].Foundry Technology,2011(8):1187-1188.
[7]
杨海娇,赵永莉,李金宝.电感耦合等离子体原子发射光谱法(ICP-AES)测定高效复合孕育剂中铝、钙、钡[J].中国无机分析化学,2015,5(3):77-79.YANG Hai-jiao,ZHAO Yong-li,LI Jin-bao.Determination of aluminium,calcium and barium in high efficiency compound inoculants by inductively coupled plasma atomic emission spectrometry (ICP-AES)[J].Chinese Journal of Inorganic Analytical Chemistry,2015,5(3):77-79.
[8]
阮桂色.电感耦合等离子体原子发射光谱(ICP-AES)技术的应用进展[J].中国无机分析化学,2011,1(4):15-18.YUAN Gui-se.Development and application of inductively coupled plasma atomic emission spectrometry[J].Chinese Journal of Inorganic Analytical Chemistry,2011,1(4):15-18.
[9]
杨祥,金泽祥.电感耦合等离子体原子发射光谱的若干进展[J].岩矿测试,2001,19(1):32-41.YANG Xiang,JIN Ze-xiang.The development of inductively coupled plasma atomic emission spectrometry[J].Rock and Mineral Analysis,2001,19(1):32-41.
[10]
叶晨亮,胡家明.电感耦合等离子体原子发射光谱法测定地质样品中镉[J].冶金分析,2016,36(6):35-39.YE Chen-liang,HU Jia-ming.Determination of cadmium in geological samples by inductively coupled plasma atomic emission spectrometry[J].Metallurgical Analysis,2016,36(6):35-39.
[11]
叶家喻,江宝林.区域地球化学勘查样品分析方法[M].北京:地质出版社,2004:226-227.
[12]
陶锐,高舸.电感耦合等离子体光发射光谱分析中无机酸基体效应研究无机酸基体效应及其机理[J].理化检验:化学分册,2005,41(1):67-71.TAO Rui,GAO Ge.Matrix effect of inorganic acids in icp-oes analysis (Ⅰ) matrix effect of inorganic acids and its mechanism[J].Chinese Journal of Analytical Chemistry,2005,41(1):67-71.
[13]
E G Chudinov,II Ostroukhova.Acid effects in ICP-AES[J].Analytical and Bioanalytical Chemistry,1989,335(1):25-33.
[14]
E Yoshimura,H Suzuki,S Yamazaki,et al.Interference by mineral acids in inductively coupled plasma atomic emission spectrometry[J].Analyst,1990,115(2):167-171.
[15]
H Ishii,K Satoh.Determination of rare earths in lanthanum oxide by inductively-coupled plasma emission derivative spectrometry[J].Talanta,1983,30(2):113-115.
[16]
A Fernández,M Murillo,N Carrión,et al.Influence of operating conditions on the effects of acids in inductively coupled plasma atomic emission spectrometry[J].Journal of Analytical Atomic Spectrometry,1994,9(3):217-221.
[17]
I B Brenner,J M Mermet,I Segal,et al.Effect of nitric and hydrochloric acids on rare earth element (REE) intensities in inductively coupled plasma emission spectrometry[J].Spectrochimica Acta Part B Atomic Spectroscopy,1995,50(s4-7):323-331.
[18]
I B Brenner,I Segal,M Mermet,et al.Study of the depressive effects of nitric acid on the line intensities of rare earth elements in inductively coupled plasma atomic emission spectrometry[J].Spectrochimica Acta Part B Atomic Spectroscopy,1995,50(s4-7):333-340.
[19]
胡珊玲,张小联,邱承洲,等.稀土镁锆中间合金中锆的测定[J].江西有色金属,2008,22(4):45-46.HU Shan-ling,ZHANG Xiao-lian,QIU Cheng-zhou,et al.Determination of zirconium in rare earth-magnesium-zirconium master alloy[J].Jiangxi Nonferrous Metals,2008,22(4):45-46.