Abstract:In order to eliminate the inhibitory effect and interference suppression of gold matrix in gold accessories detection as well as to improve the testing efficiency, the single element standard solution of Ru, Pd, Ir and Pt should be mixed to prepare multi-element standard solution, which was then added into high-purity gold matrix solution to prepare standard solution series. The stability of this mixed standard solution was tested by inductively coupled plasma atomic emission spectrometry (ICP-AES). The testing period was 12 month. The results showed that the correlation coefficients of calibration curves at different stages were higher than 0.999. The t test results also indicated that the concentration of Ru, Pd, Ir and Pt in gold system had no significant changes within a year. The prepared mixed standard solution could be stably kept for long term in darkness at 15-30 ℃.
王萍,黄准,程佑法,孙冰,田闵闵. 含金体系中钌钯铱铂混合标准溶液稳定性检验[J]. 冶金分析, 2017, 32(2): 76-80.
WANG Ping, HUANG Zhun, CHENG You-fa, SUN Bing, TIAN Min-min. Stability test of standard solutions of ruthenium, palladium, iridium, platinum in gold system. , 2017, 32(2): 76-80.
王根荣,陆慧.标准物质及其管理[J].化学分析计量,2004,11(6):59-62.WANG Gen-rong,LU Hui.Reference material and its administration[J].Chemical Analysis and Meterage,2004,11(6):59-62.
[2]
王巧云,何欣,王锐.国内外标准物质发展现状[J].化学试剂,2014,36(4):289-296.WANG Qiao-yun,HE Xin,WANG Rui.Development of reference materials in China and abroad[J].Chemical Reagents,2014,36(4):289-296.
[3]
方奕文,郝志峰,余林,等.ICP-AES法直接测定海泥中的Fe和Mn[J].分析试验室,2003,2(4):87-88.FANG Yi-wen,HAO Zhi-feng,YU Lin,et al.Determination of Fe and Mn in sea mud by ICP-AES[J].Chinese Journal of Analysis Laboratory,2003,22(4):87-88.
[4]
王干珍,汤行,叶明,等.电感耦合等离子体原子发射光谱法测定含碳质钒矿石中硅铝铁钒磷[J].冶金分析,2016,36(5):30-34.WANG Gan-zhen,TANG Xing,YE Ming,et al.Determination of silicon,aluminum,iron,vanadium and phosphorus in carbon-bearing vanadium ore by inductively coupled plasma atomic emission spectrometry[J].Metallurgical Analysis,2016,36(5):30-34.
[5]
杨晓燕,李莉,王碧璇,等.用ICP-AES法测定电镀铬废水中的铬含量[J].材料保护,2008,41(9):70-71.YANG Xiao-yan,LI Li,WANG Bi-xuan,et al.Determtnation of chromium in electroplating wastewater by ICP-AES[J].Materials Protection,2008,41(9):70-71.
王烨,颜芝.我国贵金属饰品成色检验进展[J].岩矿测试,2003,22(4):284-290.WANG Ye,YAN Zhi.Development of precious metal jewelery testing in China[J].Rock and Mineral Analysis, 2003,22(4):284-290.
[8]
姜岚.贵金属无损检测消除干扰因素对测试结果影响方法的研究[J].计量与测试技术,2010,37(9):1-3.JIANG Lan.Study on eliminating interference factors to test results in non-damage testing of precious[J].Metrology & Measurement Technique,2010,37(9):1-3.
[9]
陈永红,黄蕊,陈菲菲,等.ICP-MS测定高纯金中的杂质元素[J].黄金,2009,30(4):43-47.CHEN Yong-hong,HUANG Rui,CHEN Fei-fei,et al.Determination of impurity element in high-purty gold by ICP-MS[J].Gold,2009,30(4):43-47.
[10]
伏荣进,曲蔚,华毅超,等.ICP-AES法测定金箔的含金量[J].中国测试技术,2007(3):70-72.FU Rong-jin,QU Wei,HUA Yi-chao,et al.Determination of gold content in gold foil by ICP-AES[J].China Measurement & Test,2007(3):70-72.