Abstract:Erbium is usually used as burnable poison in nuclear reactor. The content of erbium in this type of burnable poison should be accurately determined in production process. In other words, it is necessary to measure the content of erbium in erbium nitrate solution. The analysis method of erbium in erbium nitrate solution by Xray fluorescence spectrometry (XRF) was established. The results showed that the peak shape of erbium in angle scanning was relatively complete when LiF200 crystal was selected. The peaktobackground ratio of erbium was best when 150 μmcollimator was used. In addition, the overall performance and count rate of instrument were good when the power was 40 kV×40 mA. The mass concentration of erbium in range of 115 mg/mL was linear to the strength of characteristic line ErLα. The correlation coefficient of calibration curve was 0.993 6. The erbium nitrate standard solution and actual erbium nitrate sample were determined according to the experimental method. The found results were consistent with those obtained by inductively coupled plasma atomic emission spectrometry (ICPAES). The relative standard deviations (RSD, n=6) were less than 0.7%.
周世行,石先伟.反应堆反应性及反馈机理研究[J].核电子学与探测技术,2013,33(8):955-959.ZHOU Shi-hang,SHI Xian-wei.Study on the reaction mechanism and reaction mechanism of the reactor[J]. Nuclear Electronics & Detection Technology,2013,33(8):955-959.
[2]
赵晶,刘志宏,郭德朋,等.功率压水堆堆芯燃料管理设计[J].原子能科学技术,2012,46(增刊):403-405.ZHAO Jing,LIU Zhi-hong,GUO De-peng,et al.Design of core fuel management for power pressurized water reacto[J].Atomic Energy Science and Technology,2012,46(supplement):403-405.
[3]
Chul Gyo Seo,Nam Zin Cho.A core design concept for multi-purpose research reactors[J].Nuclear Engineering and Design,2012,252:34-41.
[4]
郭纯孝,段忆祥,戴国忠,等.偏最小二乘法用于忒、钍、铒的同时测定[J].高等学校化学学报,1993,14(7):911-913.GUO Chun-xiao,DUAN Yi-xiang,DAI Guo-zhong,et al.Determination of terbium,thorium and erbium simultaneously by using partial least squares[J].Chemical Journal of Chinese Universities,1993,14(7):911-913.
[5]
刘永林,邱祖民,周萍,等.沉淀分离-ICP-MS测定金属铒中钨的研究[J].现代科学仪器,2011(5):91-93.LIU Yong-lin,QIU Zu-min,ZHOU Ping,et al.Study on the separation and determination of tungsten in the metal erbium by ICP-MS[J].Modern Scientific Instruments,2011(5):91-93.
[6]
吴承美,林云山.ICP-AES法测定钒酸钇晶体中的掺杂稀土元素铒和铕的含量[J].光谱实验室,1995(2):21-23.WU Cheng-mei,LIN Yun-shan.Content determination of rare earth element erbium and Eu in yttrium aluminate crystal by ICP-AES [J].Chinese Journal of Spectroscopy Laboratory,1995(2):21-23.
[7]
王佩佩,李霄,宋伟娇.微波消解-电感耦合等离子体质谱法测定地质样品中稀土元素[J].分析测试学报,2016(2):235-240.WANG Pei-pei,LI Xiao,SONG Wei-jiao.Determination of rare earth elements in geological samples by ICP-MS using microwave digestion [J].Journal of Instrumental Analysis,2016(2):235-240.
[8]
李景喜,朱志伟,尹晓斐,等.南大西洋中脊表层沉积物中稀土元素的含量及分布模式分析[J].分析化学,2015(1):21-26.LI Jing-xi,ZHU Zhi-wei,YIN Xiao-fei,et al.Analysis of contents and distribution patterns of rare earth elements in surface sediments of the South Mid-Atlantic Ridge[J]. Chinese Journal of Analytical Chemistry,2015(1):21-26.
[9]
吉昂,陶光仪,卓尚军,等.X射线荧光光谱分析[M].北京:科学出版社,2003:16-32.
[10]
王占明,廖志海,赵峰.X荧光光谱溶液法分析镍基合金中镍含量[J].科技纵览,2015(1):145-146.WANG Zhan-ming,LIAO Zhi-hai,ZHAO Feng.Analysis of nickel content in nickel based alloys by X fluorescence spectrometry[J].Technology Overview,2015(1):145-146.
[11]
张祥,陆晓明,金德龙,等.熔融制样-X射线荧光光谱测定不锈钢中10种组分[J].冶金分析,2016,36(1):40-44.ZHANG Xiang,LU Xiao-ming,JIN De-long,et al.Determination of ten components in stainless steel slag by X-ray fluorescence spectrometry[J].Metallurgical Analysis,2016,36(1):40-44.