Determination of arsenic in titanium dioxide by hydride generation atomic fluorescence spectrometry
WANG Yong,WANG Wei,LIU Yuan-qing,LIU Lin,GONG Hou-liang
National Quality Supervision and Testing Center of Vanadium and Titanium Products,Product Quality Supervision and Testing Institute of Panzhihua, Panzhihua 617000,China
Abstract:For the detection of arsenic in titanium dioxide, the sample was usually dissolved with nitric acid-hydrochloric acid-hydrofluoric acid system. However, this pretreatment method had the following problems: the titanium was easily hydrolyzed; the digestion time was relatively long. In the experiment, the dissolution method of titanium dioxide sample with sulfuric acid-ammonium sulfate system was proposed. The problems above were solved. Moreover, the reaction was mild. Accordingly, the determination method of arsenic in titanium dioxide by hydride generation atomic fluorescence spectroscopy (HG-AFS) was established. The results showed that the mass concentration of arsenic in range of 0.50-20 μg/L had good linear relationship with the corresponding absorbance. The linear correlation coefficient was 0.999 8. The detection limit of method was 0.05 μg/L. The interference test results indicated that the coexisting elements in matrix titanium sample did not interfere with the determination. The proposed method was applied to the analysis of actual sample, and the found results were consistent with those obtained by inductively coupled plasma mass spectrometry (ICP-MS). The relative standard deviation (RSD, n=11) was less than 5%. The recoveries of standard addition were between 95% and 101%.
胡珊,聂麦茜,卢金锁,等.镉对砷在二氧化钛上吸附性能的影响[J].环境化学,2011,30(4):739-746.HU Shan,NIE Mai-qian,LU Jin-suo,et al.Cadmium effect on arsenate adsorption on TiO2[J].Environmental Chemistry,2011,30(4):739-746.
[2]
张文莉,李慧莉.药用与食用二氧化钛中砷的测定[J].理化检验:化学分册,2002,38(2):79-80.ZHANG Wen-li,LI Hui-li.Determination of arsenic in medical and edible titanium dioxide[J].Physical Testing and Chemical Analysis Part B:Chemical Analysis,2002,38(2):79-80.
[3]
成勇.微波消解-电感耦合等离子体原子发射光谱法测定二氧化钛中微量杂质元素[J].冶金分析,2006,26(2):57-60.CHENG Yong.Determination of micro impurity elements in the titanium dioxide by inductively coupled plasma-atomic emission spectrometry with microwave digestion [J].Metallurgical Analysis,2006,26(2):57-60.
[4]
黄木辉.微波消解-石墨炉原子吸收光谱法测定纳米二氧化钛中痕量砷[J].中国无机分析化学,2013,3(4):41-44.HUANG Mu-hui.Determination of trace arsenic in nano-titanium dioxide by microwave digestion-graphite furnace atomic absorption spectrometry [J].Chinese Jorunal of Inorganic Analytical Chemistry,2013,3(4):41-44.
[5]
何晓梅,谢华林,聂西度,等.高分辨等离子体质谱法测定高纯二氧化钛中痕量杂质[J].光谱学与光谱分析,2007,27(6):1192-1196.HE Xiao-mei,XIE Hua-lin,NIE Xi-du,et al.Determination of trace impurities in high purity titanium dioxide by high resolution inductively coupled plasma mass spectrometry[J].Spectroscopy and Spectral Analysis,2007,27(6):1192-1196.
[6]
成勇.微波消解-电感耦合等离子体质谱法测定二氧化钛中痕量元素[J].冶金分析,2009,29(10):7-12.CHENG Yong.Determination of trace elements in titanium oxide by microwave digestion inductively coupled plasma mass spectrometry [J].Metallurgical Analysis,2009,29(10):7-12.
[7]
何晓梅,符靓,聂西度,等.微波消解-氢化物发生-原子荧光光谱法测定二氧化钛中痕量砷和锑[J].冶金分析,2009,29(11):54-56.HE Xiao-mei,FU Liang,NIE Xi-du,et al.Simultaneous determination of trace arsenic and antimony in titanium dioxide by microwave digestion-hydride generation-atomic fluorescence spectrometry[J].Metallurgical Analysis,2009,29(11):54-56.
[8]
张效伟,张召香,宋琦,等.对喷式氢化物发生原子荧光光谱法同时测定烟叶中痕量砷和锑[J].分析化学,2006,34(10):1448-1450.ZHANG Xiao-wei,ZHANG Zhao-xiang,SONG Qi,et al.Simultaneous determination of trace As and Sb in tobacco samples by opposite spray hydride generation atomic fluorescence spectrometry[J].Chinese Journal of Analytical Chemistry,2006,34(10):1448-1450.
[9]
任占军,郝贵奇,尹长田,等.微波消解-氢化物发生原子荧光光谱法测定污泥中汞和砷[J].冶金分析,2014,34(3):52-56.REN Zhan-jun,HAO Gui-qi,YIN Chang-tian,et al.Determination of mercury and arsenic in sludge by microwave digestion-hydride generation atomic fluorescence spectrometry[J].Metallurgical Analysis,2014,34(3):52-56.
[10]
武素茹,王虹,李权斌,等.氢化物发生-原子荧光光谱法测定冰铜中砷[J].冶金分析,2014,34(1):67-70.WU Su-ru,WANG Hong,LI Quan-bin,et al.Determination of arsenic in copper matte by hydride generation-atomic fluorescence spectrometry[J].Metallurgical Analysis,2014,34(1):67-70.