Determination of cadmium in steel for cutlery by inductively coupled plasma atomic emission spectrometry after separation with small ion exchange column
LIU Feng1,WANG Hui2,WU Cheng1,YU Lu1,WANG Guo-xin1,ZHOU Jin-fan3
1.Changshu Entry-Exit Inspection and Quarantine Bureau, Changshu 215500,China; 2.Jiangsu Entry-Exit Inspection and Quarantine Bureau, Nanjing 210001,China; 3.Editorial Office, Journal of Inspection and Quarantine Science,Beijing 100020, China
Abstract:The distribution coefficient of iron and cadmium in hydrochloric acid with various concentrations on DOWEX 1×X8 anion exchange resin was determined by Strelow method. The results showed that the Kd value of iron (Ⅲ) in 1 mol/L hydrochloric acid was less than 10 mL/g, indicating that it could not be adsorbed on the resin. However, the Kd value of cadmium (Ⅱ) was 2 281 mL/g, indicating that it could be strongly adsorbed on the resin. Therefore, iron (Ⅲ) and cadmium (Ⅱ) could be effectively separated. The steel sample for cutlery was dissolved with hydrochloric acid,then the sample solution flowed through the small column which was packed with DOWEX 1×X8 anion exchange resin. The iron (Ⅲ) in solution could pass through the column, while cadmium (Ⅱ) would be adsorbed onto the column, realizing the effective separation and enrichment of cadmium and iron. Then, the cadmium (Ⅱ) on column was eluted with 1 mL of 1.6 mol/L nitric acid. The content of cadmium in collected solution was determined by inductively coupled plasma atomic emission spectrometry (ICP-AES).Consequently,the determination method of micro cadmium in steel for cutlery by ICP-AES after separation with small ion exchange column was established. The mass concentration of cadmium in range of 0.010-0.10 mg/L was linear to the emission intensity. The linear correlation coefficient of calibration curve was 0.999 9. The detection limit of cadmium was 0.004 g/mL (which was equivalent to the mass fraction of 0.04 μg/g of cadmium in actual sample). The content of cadmium in steel for cutlery was determined according to the experimental method. The relative standard deviation (RSD, n=7) was 5.8%-7.3%. The recoveries were between 90% and 100%.
刘 烽,王 慧,吴 骋,俞 璐,王国新,周锦帆. 小型离子交换柱分离-电感耦合等离子体原子发射光谱法测定餐具用钢中镉[J]. 冶金分析, 2016, 36(4): 23-27.
LIU Feng. Determination of cadmium in steel for cutlery by inductively coupled plasma atomic emission spectrometry after separation with small ion exchange column. , 2016, 36(4): 23-27.
Chen S C,Shiue M Y,Yang M H.Microwave digestion and matrix separation for the determination of cadmium in urine samples by electrothermal atomization atomic absorption spectrometry using a fast temperature program[J].Fresenius Journal of Analytical Chemistry,1997(8):1192-1197.
[2]
Waalkes M P-Cadmium carcinogenesis[J].Mutation Research/Fundamental & Molecular Mechanisms of Mutagenesis,2003,533:107-120.
[3]
Danijela D C,Milica N,Zivorad M,et al.Effect of supplemental magnesium on the kidney levels of cadmium, zinc and copper of mice exposed to toxic levels of cadmium[J].Biological Trace Element Reasearch,2006,114:281-291.
[4]
宋传旺,庞晋山.电感耦合等离子体原子发射光谱同时测定不锈钢厨具铬、镍、镉、铅、砷迁移量[J].理化检验:化学分册,2010,46(5):528-530.SONG Chuan-wang,PANG Jin-shan.Simultaneous ICP-AES determination of migration amounts of Cr,Ni,Cd,Pb and As in stainless steel cooking utensil[J].Physical Testing and Chemical Analysis Part B:Chemical Analysis,2010,46(5):528-530.
[5]
郑国经.电感耦合等离子体原子发射光谱分析仪器与方法的新进展[J].冶金分析,2014,34(11):1-10.ZHENG Guo-jing.New advances in inductively coupled plasma atomic emission spectrometric instruments and methods[J].Metallurgical Analysis,2014,34(11):1-10.
[6]
蔡鹭欣,普旭力,邹建龙,等. ICP-AES法测定氧化铁皮中铅、铬、镉[J].福建分析测试,2011,20(6):54-56.CAI Lu-xin,PU Xu-li,ZOU Jian-long,et al.Determination of Pb,Cr and Cd in mill scale by inductively coupled plasma atomic emission spectrometry[J].Fujian Analysis & Testing,2011,20(6):54-56.
[7]
周明辉,唐志锟,宋武元,等.六亚甲基四胺剥离-电感耦合等离子体原子发射光谱法测定钢材镀锌层中铅镉砷[J].冶金分析,2012,32(1):48-51.ZHOU Ming-hui,TANG Zhi-kun,SONG Wu-yuan,et al.Determination of lead,cadmium and arsenic in the coating of zinc coated steel sheets by inductively coupled plasma atomic emission spectrometry after stripping with hexamine[J].Metallurgical Analysis,2012,32(1):48-51.
[8]
Matsumiya H,Sakane Y,Hiraide M.Determination of trace impurities in high-purity iron using salting-out of polyoxyethylene-type surfactants[J].Analytica Chimica Acta,2009(1):86-90.
[9]
Matsumiya H,Furuzawa S,Hiraide M.Removal of an iron matrix with polyoxyethylene-type surfactant-coated amberlite XAD-4 for the determination of trace impurities in high-purity iron[J].Analytical Chemistry,2005,77(16):5344-5348.
[10]
Fujimoto K,Chino A.Determination of trace amounts of mercury, lead and cadmium in steels by ICP-MS after ion exchange chromatographic separation[J].Bunseki Kagaku,2006,55(4):245-249.
[11]
Tokahoglu S,Kartal S,Elci L.Determination of some trace elements in high-purity aluminium, zinc and commercial steel by AAS after preconcentration on Amberlite XAD-1180 resin[J].Microchimica Acta,1997,127(3-4):281-286.
[12]
Xu Y Y,Wang H,Wang G X,et al.Determination of trace amounts of rare-earth elements in clean steel by inductively coupled plasma optical emission spectrometry after removal of iron matrix with anion-exchange resin[J].Applied Spectroscopy,2010,64(5):543-546.
[13]
Strelow F W E,Chem A.An ion exchange selectivety scale of cations based on equilibrium distribution coeffients[J].Analytical Chemistry,1960,32(9):1185-1188.
[14]
刘烽,王慧,王国新,等.铁及镉在DOWEX 1-X8阴离子交换树脂上分配系数的测定及其用于钢中微量镉的分析[J].化学试剂,2013,35(5):432-434.LIU Feng,WANG Hui,WANG Guo-xin,et al.Determination of distribution coefficients of iron and cadmium on DOWEX 1-X8 anion exchange resin and application to determination of cadmium in steel[J].Chemical Reagents,2013,35(5):432-434.
[15]
谢晓雁,吴文启,李奋,等.离子交换分离-电感耦合等离子体原子发射光谱法测定锰矿中铊[J].冶金分析,2015,35(8):61-65.XIE Xiao-yan,WU Wen-qi,LI Fen,et al.Determination of thallium in manganese ore by inductively coupled plasma atomic emission spectrometry after ion exchange separation[J].Metallurgical Analysis,2015,35(8):61-65.