Simultaneous determination of cobalt and palladium by 5-(5-iodine-2-pyridylazo)-2,4-diaminotoluene dual wavelength overlapping spectrophotometry
HAN Quan1,2,HAO Tian-tian2,HUO Yan-yan1,JIN Zhu1,YANG Xiao-hui1
1.School of Chemistry and Chemical Engineering, Xi’an University, Xi’an 710065,China; 2.School of Chemistry and Chemical Engineering, Yan’an Universty, Yan’an 716000,China
Abstract:A novel simultaneous determination method for cobalt and palladium was established by dual wavelength overlapping spectrophotometry with 5-(5-iodine-2-pyridylazo)-2,4-diaminotoluene (5-I-PADAT) as chromogenic reagent. The experimental results showed that in the medium of 0.6~2.4 mol/L HClO4, palladium reacted with 5-I-PADAT to form a stable complex, but cobalt could not in such a strong acidic medium. Cobalt reacted with 5-I-PADAT in the pH 3.6~10 buffer medium to form a stable complex which could be converted to another protonated species with higher absorption characteristics when the acidity was increased to 0.6-3.0 mol/L HClO4. It was also found that, the complex of cobalt (Ⅱ) and palladium(Ⅱ) and 5-I-PADAT both have two very close absorption peaks, with strong peak at 580 nm and 583 nm and weak peak at 532 nm and 543 nm, respectively. Based on the difference of chromogenic acidity of cobalt(Ⅱ) and palladium(Ⅱ) with 5-I-PADAT, the absorbance additivity, etc., a novel simultaneous determination method for cobalt and palladium by dual-wavelength overlapping spectrophotometry was estblished. Beer's law was obeyed within cobalt and palladium concentration range of 0-0.4 μg/mL and 0-1.0 μg/mL, respectively. The apparent molar absorption coefficients of cobalt and palladium were 2.17×105 L·mol-1·cm-1 and 1.10×105 L·mol-1·cm-1, and the sensitivity was improved by 1.75 and 1.53 times higher than single wavelength, respectively. The method has been applied to simultaneous determination of cobalt and palladium in catalyst and ore samples, whose results were consistent with the recommended values. The relative standard deviation(RSD,n=6)were 0.50%-2.3%(cobalt)and 1.0%-1.4%(palladium).
Ivanov V M, Ershova N I, Figurovskaya V N, et al. Optical and chromaticity characteristics of cobalt and palladium 4-(2-pyridylazo) resorcinates[J] . Journal of Analytical Chemistry, 2001,56(2):143-148.
[2]
Eskandari H, Saghseloo A G. Second and first-derivative spectrophotometry for efficient simultaneous and individual determination of palladium and cobalt using 1-(2-pyridylazo)-2-naphthol in sodium dodecylsulfate micellar media[J]. Anal. Sci., 2003, 19(11):1513-1518.
[3]
刘根起, 程永清,张光.5-(5-硝基-2-吡啶偶氮)-2,4-二氨基甲苯吸光光度法同时测定铜和钯[J]. 理化检验:化学分册(Physical Testing and Chemical Analysis Part B: Chemical Analysis)),2004,40(2):69-74.
[4]
Chamjangali M A, Bagherian G, Azizi G. Simultaneous determination of cobalt, nickel and palladium in micellar media using partial least square regression and direct orthogonal signal correction[J]. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2005,62(1-3):189-196.
[5]
韩权,杨晓慧,王媚,等.2-(3,5-二氯-2-吡啶偶氮)-5-二甲氨基苯胺光度法同时测定铑与钯[J]. 分析试验室(Chinese Journal of Analysis Laboratory), 2009,28(5):76-79.
[6]
王晓玲,孙家娟,杨连利,等. 5-(5-硝基-2-吡啶偶氮)-2,4-二氨基甲苯光度法同时测定钻和钯[J].理化检验:化学分册(Physical Testing and Chemical Analysis Part B: Chemical Analysis)),2004,40(10):581-583.
[7]
杨晓慧,韩权,李海维.4-(5-硝基-2-吡啶偶氮)-1,3-二氨基苯光度法同时测定钴和钯[J].岩矿测试(Rock and Mineral Analysis),2008,27(2):113-116.
[8]
Pouretedal H R, Sononi P, Keshavarz M H,et al. Simultaneous determination of cobalt and iron using first-derivative spectrophotometric and H-point standard addition methods in michllar media[J]. Chemistry, 2009,18 (3):22-35.