Abstract:A review of the analytical methods for micro and trace germanium in geological samples was given.The sample pretreatment methods including acid dissolution and alkali fusion, the separation and enrichment methods, the determination methods for germanium, including polarography, graphite furnace atomic absorption spectrometry, atomic fluorescence spectrometry, inductively coupled plasma atomic emission spectrometry and inductively coupled plasma mass spectrometry were introduced, and the prospect of the separation and analysis methods for germanium was discussed.
Li Zai jun, Zhou Xia, Liu Hui zhen, et al. Development of spectrophotometric method for determination of germanium[J] Reviews in Analytical Chemistry, 2007, 26 (1): 23-41.
[10]
邱罡. 光度法测定锗的研究进展[J]. 理化检验:化学分册(Physical Testing and Chemical Analysis : Part B Chemical Analysis), 2011, (9):1123-1128.
[11]
刘月芬. 示波极谱直接测定方铅矿中微量锗[J]. 分析试验室(Chinese Journal of Analysis Laboratory), 1988, 7(2):35-36.
[12]
Julio César Aguilar, Josefina de Gyves. Determination of germanium(IV) in sulphide ores by differential pulse polarography in pyrogallol-sulfuric acid media[J]. Anal. Chim. Acta, 1995, 306(2-3): 243-247.
[13]
郑克勤, 徐立青, 李卓先. 示波极谱法测定1:5万区调样品中的痕量锗[J]. 岩矿测试(Rock and Mineral Analysis), 1995, 11(5):257-259.
[14]
木志坚. 土壤全锗的催化极谱测定[J]. 分析化学(Chinese Journal of Analytical Chemistry), 1998, 26(7):916-916.
[15]
戴锦明. 催化极谱法测定岩矿样品中痕量锗[J]. 岩矿测试(Rock and Mineral Analysis), 1998, 14(4):241-241, 286.
张渝阳, 邓桂春, 宛彤昕, 等. 生物样品中痕量锗的分析进展[J]. 辽宁大学学报:自然科学版 (Journal of Liaoning University :Natural Science Edition), 2003, 30(2):185-190.
[20]
唐维学, 熊晓燕, 周志平. 微量镓分析的进展[J]. 材料研究与应用(Materials Research and Application), 2008, 2(1):75-79.
[21]
温彬宇, 王光信, 张崇淼, 等.微量镓的分析方法评述及展望[J]. 昆明理工大学学报:自然科学版(Journal of Kunming University of Science and Technology:Natural Science Edition), 2003, 28(6): 23-27.
[22]
张扬祖. 原子吸收光谱分析应用基础[M]. 上海:华东理工大学出版社, 2007.
[23]
Kaya M, Volkan M. Germanium determination by flame atomic absorption spectrometry: An increased vapor pressure-chloride generation system[J]. Talanta, 2011, 84(1):122-126.
Matsusaki K, Okada K, Oishi T, et al. Matrix modification with metal nitrates and organic compounds for the determination of germanium by absorption spectrometry[J]. Analytical Sciences, 1994, 10:281-285.
杨密云, 郭小伟. 氢化物无色散原子荧光法测定地球化学样品中的锗[J]. 分析化学(Chinese Journal of Analytical Chemistry), 1986, 14(5):333-336.
[37]
张勤, 范凡. 氢化物-原子荧光光谱法直接测定地质物料中痕量锗[J]. 岩矿测试(Rock and Mineral Analysis), 1996, 15(4):286-289.
[38]
许庆福, 周长祥, 张文娟. 地球化学样品中痕量锗的氢化物发生-原子荧光法测定[J]. 山东国土资源(Land and Resources in Shandong Province), 2001, 17(6):51-54.
[39]
Shi Jian bo, Tang Zhi yong, Tan Chun hua, et al. Determination of trace amounts of germanium by flow injection hydride generation atomic fluorescence spectrometry with on-line coprecipitation[J]. Talanta, 2002, 56(4): 711-716.
[40]
覃祚明. 氢化物发生-原子荧光光谱法测定锌精矿中的锗[J]. 材料研究与应用(Materials Research and Application), 2002, 12(z1):66-69.
[41]
Li Gang, Li Wen li, Zhong Guan ping, et al. L-cysteine enhanced hydride generation for atomic fluorescence spectrometric determination of germanium in geological samples[J]. Spectroscopy Letters, 2003, 36(4):275-285.
肖灵, 张培新, 胡月华. 原子荧光光谱法测定地质样品中的痕量锗[J]. 岩矿测试(Rock and Mineral Analysis), 2004, 23(3):231-234.
[44]
董亚妮, 田萍, 熊英, 等. 氢化物发生-原子荧光光谱法测定铜铅锌矿石中的微量锗[J]. 岩矿测试(Rock and Mineral Analysis), 2010, 29(4):395-398.
[45]
Li Jing, Zhao Shilan, Zhang Zhao hui, et al. Determination of trace germanium in marine sediments by hydride generation-atomic fluorescence spectrometry (HG-AFS)[J]. Journal of Ocean University of China :English Edition, 2004, 3(2):179-182.
[46]
辛仁轩. 等离子体发射光谱分析[M]. 北京:化学工业出版社, 2011:354-355.
[47]
Rigby C, Brindle I D. Determination of arsenic, antimony, bismuth, germanium, tin, selenium and tellurium in 30% zinc sulfate solution by hydride generation inductively coupled plasma atomic emission spectrometry [J]. Journal of Analytical Atomic Spectrometry, 1999, 14(2), 253-258.
[48]
吴列平, 袁玄晖. 不同氢化反应条件下原子发射光谱同时测定锗锡砷锑铋[J]. 岩矿测试(Rock and Mineral Analysis), 1999, 18(3):220-224.
[49]
Choi M S, Kim K J. Determination of trace amount of germanium in rocks and sediments by hydride vapor generation ICP-AES[J]. Journal Korean Chemical Society, 1997, 41(8):399-405.
[50]
Hiroaki Tao, Akira Miyazaki. Determination of germanium, arsenic, antimony, tin and mercury at trace levels by continuous hydride generation-helium microwave-induced plasma atomic-emission spectrometry[J]. Analytical Sciences February, 1991, 7:55-59.
[51]
张晓惠, 侯明轶.微波诱导等离子体原子发射光谱法测定铍铬钼钒锆锗的研究[J]. 岩矿测试(Rock and Mineral Analysis), 1992, 11(3):221-224.
[52]
Grotti Marco, Lagomarsino Cristina, Frache Roberto. Multivariate study in chemical vapor generation for simultaneous determination of arsenic, antimony, bismuth, germanium, tin, selenium, tellurium and mercury by inductively coupled plasma optical emission spectrometry [J]. Journal of Analytical Atomic Spectrometry, 2005, 20(12):1365-1373.
[53]
李冰, 杨红霞.电感耦合等离子体质谱原理和应用[M]. 北京:地质出版社, 2005.
[54]
刘虎生.电感耦合等离子体质谱技术与应用[M]. 北京:化学工业出版社, 2007.
[55]
张培新, 黄光明, 董丽, 等.电感耦合等离子体质谱法同时测定地质样品中锗碘[J]. 岩矿测试(Rock and Mineral Analysis), 2005, 24(1):36-39.
[56]
李刚, 曹小燕. 电感耦合等离子体质谱法测定地质样品中锗和镉的干扰及校正[J]. 岩矿测试(Rock and Mineral Analysis), 2008, 27(3):197-200.
赵朝辉, 李可及, 邹利平, 等. ICP-MS同时测定土壤样品中的镓铟锗[J]. 矿产综合利用(Multipurpose Utilization of Mineral Resources), 2012, (3):52-54.
[59]
Mortlocka R A, Froelich P N. Determination of germanium by isotope dilution hydride generation inductively coupled plasma mass spectrometry [J]. Anal. Chim. Acta, 1996, 332(2-3):277-284.
[60]
Makishima A, Nakamura E. Determination of Ge, As, Se and Te in silicate samples using isotopedilution-internal standardisation octopole reaction cell ICP-QMS by normal sample nebulisation[J]. Geostandards and Geoanalytical Research, 2009, 33(3):369-384.