Review of the research on the determination of trace iron with spectrophotometry
LI Guo-qiang1, 2, YANG Jian-jun2, HE Jia-hong1, 2, SONG Zhong-rong2, XU Qiang*2
1. Chemistry and Chemical Engineering, Chongqing University, Chongqing 400044, China;2. College of Materials and Chemical Engineering, Chongqing University of Arts and Sciences, Chongqing 402160, China
Abstract:A review on the progress in recent years (2000-2012) of the spectrophotometric method for the determination of trace iron was presented. The content concerned the direct significant (faded) color spectrohotometry, catalytic kinetic spectrophotometry, inhibitory kinetic spectrophotometry, fluorospectrometry, chemical luminescence analysis and coupling techniques. The reaction medium, detection limit, linear range and the practical application object of different analytical methods are summarized and outlined. In order to improve the determination of iron by spectrophotometry, the proposal including the enhancement of the instruments’ capabilities to increase the sensitivity and reduce the determination error; the development of highly sensitive, selective, stable and environmental-friendly coloration reagents to improve the detection methods; and the combination with highly effective separation and enrichment detection techniques to reduce the interference and improve the systematic accuracy was proposed.
李国强, 杨建君, 何家洪, 宋仲容, 徐强. 分光光度法测定铁的研究进展[J]. 冶金分析, 2014, 34(1): 34-44.
LI Guo-qiang, YANG Jian-jun, HE Jia-hong, SONG Zhong-rong, XU Qiang. Review of the research on the determination of trace iron with spectrophotometry. , 2014, 34(1): 34-44.
David Meyer, Ralf D Prien, Olaf Dellwig, et al. In situ determination of iron in the anoxic zone of the central baltic sea using ferene as spectrophotometric reagent[J] .Marine Chemistry, 2012, 130-131: 21-27.
[4]
刘希洋. 邻菲啰啉分光光度法测定海水中总铁[J] . 环境监测管理与技术(The Administration and Technique of Environmental Monitoring), 2008, 20(4): 49-50.
Peng Yuanzhen, Yuan Dongxing, Huang Yongming, et al. Membrane preconcentration of iron in seawater samples and on-site determination in spectrophotometry[J] . Chinese Journal of Oceanology and Limnology, 2012, 30(2): 315-320.
Paulo C Nascimento, Cristiane L Jost, Marcos V Guterres, et al. Simultaneous determination of Al and Fe in post-hemodialysis fluids by spectrophotometry and multivariate calibration[J] . Talanta, 2006, 70: 540-545.
[10]
Mohammad Ali Taher. Application of the ion pair of 1, 10-phenanthroline and tetraphenylborate for preconcentration of trace iron and determination by derivative spectrophotometry[J] . Chem. Anal., 2002, 47(1): 147-158.
Tang Yinan, Yuan Yuan, Chen Xing, et al. Highly sensitive determination of iron ions in water with bromopyrogallol red by light absorption ratio variation spectrophotometry[J] . Instrumentation Science and Technology, 2009, 37: 204-217.
E Y Hashem, M S Abu-Bakr, S M Hussain. Interaction of nickel with 4-(2'-benzothiazolylazo) salicylic acid (BTAS) and simultaneous first-derivative spectrophotometric determination of nickel and iron[J] . Spectrochimica Acta, Part A, 2003, 59: 761-769.
Magda Ali Akl. Preconcentration extractive separation, speciation and spectrometric determination of iron in environmental samples[J] . Microchemical Journal, 2003, 75: 199-209.
[17]
Nadia Aguerssif, Mohamed Benamor, Malek Kachbi, et al. Simultaneous determination of Fe and Al by first-derivative spectrophotometry and partial least-squares (PLS-2) method-Application to post-haemodialysis fluids[J] . Journal of Trace Elements in Medicine and Biology, 2008, 22: 175-182.
[18]
Kiran K. Spectrophotometric determination of iron in water samples using 3-hydroxy benzyl amino benzoic acid[J] . International Journal of Environmental Sciences, 2012, 3(1): 201-208.
[19]
K Zarei, M Atabati, Z Malekshabani. Simultaneous spectrophotometric determination of iron, nickel and cobalt in micellar media by using direct orthogonal signal correction-partial least squares method[J] . Analytica Chimica Acta, 2006, 556: 247-254.
Kyriakos A Riganakosa, Panayiotis G Veltsistas. Comparative spectrophotometric determination of the total iron content in various white and red Greek wines[J] . Food Chemistry, 2003, 82: 637-643.
[22]
E Viollier, P W Inglett, K Hunter, et al. The ferrozine method revisited:Fe/Fe determination in natural waters[J] . Applied Geochemistry, 2000, 15: 785-790.
[23]
M Ines Toral, Carolina Paipa, Jessica Narvaez, et al. Simultaneous determination of iron and ruthenium by preconcentration on sulfopropyl sephadex cation exchanger[J] . Microchemical Journal, 2002, 73: 317-324.
[24]
邱小香. 分光光度法测定水中全铁的含量[J] . 西南民族大学学报:自然科学版(Journal of Southwest University for Nationalities:Natrual Science Edition), 2011, 37(1): 111-113.
[25]
M G Gioia, A M Di Pietra, R Gatti. Validation of a spectrophotometric method for the determination of iron impurities in dosage forms[J] . Journal of Pharmaceutical and Biomedical Analysis, 2002, 29: 1159-1164.
[26]
M M Seleim, M S Abu-Bakr, E Y Hashem, et al. Simultaneous determination of aluminum and iron by first-derivative spectrophotometry in alloys[J] . Journal of Applied Spectroscopy, 2009, 76(4): 554-563.
卢晓红. 邻菲罗啉法测定循环水中铁离子含量的不确定度评定[J] . 化工技术与开发(Technology & Development of Chemical Industry), 2012, 41(1): 32-40.
[29]
T N Kiran Kumar, H D Revanasiddappa. Rapid and sensitive spectrophotometric determination of trace amounts of iron using leuco Xylene cyanol FF[J] . Anal. Bioanal. Chem., 2003, 376: 1126-1130.
倪秀珍, 王晓菊. 表面活性剂增敏催化动力学光度法测定食品中的痕量铁[J] . 食品研究与开发(Food Research and Development), 2008, 29(9): 113-115.
[36]
Zhu Q R, Sun D M, Wang L. Simultaneous determination of iron and molybdenum by extraction catalytic spectrophotometry[J] . Spectroscopy and Spectral Analysis, 2002, 22(6): 1072-1074.
Josiane Meire Tolotti Carneiro, Ana Cristi Basile Dias, Elias Ayres Guidetti Zagatto, et al. Spectrophotometric catalytic determination of Fe in estuarine waters using a flow-batch system[J] . Analytica Chimica Acta, 2002, 455: 327-333.
莎仁, 嘎日迪. 催化动力学光度法测定痕量铁的研究[J] . 内蒙古师范大学学报:自然科学汉文版(Journal of Inner Mongolia Normal University: Natural Science Edition), 2005, 34(2): 194-196.
[45]
尹庚明, 马晓鸥, 康思琦. 偶氮胭脂红B指示反应动力学光度法测定痕量铁[J] . 理化检验-化学分册(Physical Testing and Chemical Analysis Part B : Chemical Analysis), 2005, 41(7): 515-517.
[46]
李少旦, 李贵荣. 过硫酸铵氧化邻甲氧基酚催化光度法测定水中痕量铁[J] . 微量元素与健康研究(Studies of Trace Elements and Health), 2005, 22(1): 44-45.
[47]
Zhou Y, Li Y Q, Yang J G, et al. Simultaneous determination of copper and iron by flow-injection catalytic kinetic spectrophotometry with multi-channel detector[J] . Spectroscopy and Spectral Analysis, 2003, 23(2): 374-376.
Hu Weihua, Zhai Qingzhou, Lin Xue. Study of the catalytic kinetic spectrophotometry of iron-(dibromo-p-methyl-arsenazo)-potassium bromate[J] . Asian Journal Chemistry, 2012, 24(8): 3625-3628.
金贞淑, 赵晔, 达古拉, 等. 催化动力学光度法测定微量铁的研究-Fe-结晶紫-H2O2体系[J] . 内蒙古民族大学学报: 自然科学版(Journal of Inner Mongolia University for Nationalities), 2001, 16(3): 247-248.
[58]
He C Y, Wu G H, Cheng Q, et al. Simultaneous determination of copper and iron by catalytic kinetic spectrophotometry[J] . Spectroscopy and Spectral Analysis, 2004, 24(6): 730-732.
龚仁敏, 朱升学, 李恩, 等. Fe-H2O2-丽春红-1, 10-菲罗啉体系催化动力学光度法测定痕量铁[J] . 理化检验-化学分册(Physical Testing and Chemical Analysis Part B: Chemical Analysis), 2000, 36(10): 445-446.
王文元, 吴瑕. 愈创木酚催化光度法测定痕量铁[J] . 理化检验-化学分册(Physical Testing and Chemical Analysis Part B: Chemical Analysis), 2011, 47: 633-639.
[70]
Ni Yongnian, Huang Chunfang, Serge Kokot. Simultaneous determination of iron and aluminium by differential kinetic spectrophotometric method and chemometrics[J] . Analytica Chimica Acta, 2007, 599: 209-218.
[71]
邢建华, 信建豪, 郭志刚, 等. 催化动力学光度法测定植物蛋白饮料中痕量铁[J] . 理化检验-化学分册(Physical Testing and Chemical Analysis Part B: Chemical Analysis), 2012, 48(6): 731-734.
[72]
S Lunvongsa, M Oshima, S Motomizu. Determination of total and dissolved amount of iron in water samples using catalytic spectrophotometric flow injection analysis[J] . Talanta, 2006, 68: 969-973.
Li Yuanqian, Yang Jingguo, Zhou Ying, et al. A new setup of flow injection-diode array detection-laser induced fluorescence spectrophotometry for simultaneous determination of copper and iron in food samples[A] . In: Righini GC, Consortini A. Proceedings of the society of photo-optical instrumentation engineers (SPIE)[C] . Florence: Optics for the Quality of Life, 2003, 4829: 534-536.
[80]
乔善宝, 焦昌梅. 氯丙嗪荧光光度法测定痕量铁[J] . 理化检验-化学分册(Physical Testing and Chemical Analysis Part B: Chemical Analysis), 2006, 42(12): 1043-1044.
[81]
王兴民, 滕秀兰. 罗丹明6G荧光猝灭法测定农产品中痕量铁[J] . 理化检验-化学分册(Physical Testing and Chemical Analysis Part B: Chemical Analysis), 2008, 44: 35-37.
Koichi Oguma, Osamu Yoshioka. Flow-injection simultaneous determination of iron and copper and of iron and palladium based on photochemical reactions of thiocyanato-complexes[J] . Talanta, 2002, 58: 1077-1087.
张衍林. 流动注射分离富集-火焰原子吸收光谱法测定烧碱中的铁铜镍[J] . 理化检验-化学分册(Physical Testing and Chemical Analysis Part B: Chemical Analysis), 1999, 35(4): 174-175.
[92]
P Ampan, S Lapanantnoppakhun, P Sooksamiti, et al. Determination of trace iron in beer using flow injection systems with in-valve column and bead injection[J] . Talanta, 2002, 58: 1327-1334.
[93]
Huang Yongming, Yuan Dongxing, Dai Minhan, et al. Reverse flow injection analysis method for catalytic spectrophotometric determination of iron in estuarine and coastal waters:A comparison with normal flow injection analysis[J] . Talanta, 2012, 93: 86-93.
[94]
Yuan Dong, Fu Dayou. Flow-injection determination of iron based on its catalysis on the oxidation reaction of xylenol orange by potassium bromate[J] . Analytical Letters, 2011, 44: 1-3.
[95]
S Lunvongsa, T Takayanagi, M Oshima, et al. Novel catalytic oxidative coupling reaction of N, N-dimethyl-p-phenylenediamine with 1, 3-phenylenediamine and its applications to the determination of copper and iron at trace levels by flow injection technique[J] . Analytica Chimica Acta, 2006, 576: 261-269.
[96]
D M C Gomes, M A Segundoa, J L F C Lima, et al. Spectrophotometric determination of iron and boron in soil extracts using a multi-syringe flow injection system[J] . Talanta, 2005, 66: 703-711.
[97]
Leonardo S G Teixeira, Fabio R P Rocha. A green analytical procedure for sensitive and selective determination of iron in water samples by flow-injection solid-phase spectrophotometry[J] . Talanta, 2007, 71: 1507-1511.
Bowie A R, Sedwick P N, Worsfold P J. Analytical intercomparison between flow injection-chemiluminescence and flow injection-spectrophotometry for the determination of picomolar concentrations of iron in seawater[J] . Limnology and Oceanography-methods, 2004, 2: 42-54.
Hayati Filik, Derya Giray. Cloud point extraction for speciation of iron in beer samples by spectrophotometry[J] . Food Chemistry, 2012, 130: 209-213.
[102]
Kazemi E, Shokoufi N, Shemirani F. Speciation and preconcentration of iron by cloud point extraction combined with fibre optic linear array detection Spectrophotometry[J] . Chemical Speciation and Bioavailability, 2011, 23(4): 249-254.
[103]
Liang Pei, Sang Hongbo, Zhimei Sun. Cloud point extraction and graphite furnace atomic absorption spectrometry determination of manganese and iron in water samples[J] . Journal of Colloid and Interface Science, 2006, 304: 486-490.
[104]
Ilknur Durukan, Cigdem Arpa Sahin, Nuray Satiroglu, et al. Determination of iron and copper in food samples by flow injection cloud point extraction flame atomic absorption spectrometry[J] . Microchemical Journal, 2011, 99: 159-163.
[105]
Cigdem Arpa Sahin, Ilknur Tokgoz, Sema Bektas. Preconcentration and determination of iron and copper in spice samples by cloud point extraction and flow injection flame atomic absorption spectrometry[J] . Journal of Hazardous Materials, 2010, 181: 359-365.
[106]
Giokas D L, Paleologos E K, Karayannis M I. Speciation of Fe and Fe by the modified ferrozine method, FIA-spectrophotometry, and flame AAS after cloud-point extraction[J] . Anal. Bioanal. Chem., 2002, 373: 237-243.