Simultaneous determination of trace arsenic, antimony, selenium and tellurium in pure copper by hydride generation-four-channel non-dispersive atomic fluorescence spectrometry
NI Ying-rui, LI Zhong-xi, LI Hai-tao,et al
(1.Northwest Nonferrous Geological Research Institute, Xian 710054, China;
2.Xi’an Qinjing Limited Liability Company of Shannxi Gold, Xian 710054, China;
3.Xi'an Xieli Power Science and Technology Co.,Ltd., Xian 710119, China)
Abstract:After samples were dissolved by nitric acid, lanthanum hydroxide was used to co-precipitate As, Sb, Se, and Te for separation with copper substrate in ammonia medium,and As, Sb, Se, and Te in pure copper were simultaneously determined by hydride generation-four-channel non-dispersive atomic fluorescence spectrometry. Hydride generation conditions and operation parameters for simultaneous determination of four elements were optimized. The results showed that, under optimal conditions, the detection limit of As, Sb, Se and Te were 0.04, 0.05, 0.04 and 0.03 ng/mL respectively, and relative standard deviation (RSD, n=7) were 0.97%, 0.77%, 0.57 % and 1.0% respectively for 20 ng/mL As, Sb and 10 ng/mL Se, Te mixed standard solution. This method was applied to simultaneous determination of As, Sb, Se, and Te in actual samples. The determination results had no significant difference with those obtained by national standard method, and the relative standard deviation was 7.0% with recoveries of 94%-105%.
倪迎瑞,,李中玺,,李海涛,,秦 靖,,张圣杰,,薛振宇,,张 燕 . 氢化物发生-四通道无色散原子荧光光谱法同时测定纯铜中的痕量砷锑硒碲[J]. 冶金分析, 2012, 32(9): 26-29.
NI Ying-rui, LI Zhong-xi, LI Hai-tao,et al. Simultaneous determination of trace arsenic, antimony, selenium and tellurium in pure copper by hydride generation-four-channel non-dispersive atomic fluorescence spectrometry. , 2012, 32(9): 26-29.
[1] 赵学沛, 沙艳梅, 王明军, 等. 电感耦合等离子体原子发射光谱法( ICP-AES)测定纯铜中多种杂质元素[J]. 华南地质与矿产(Geology and Mineral Resources of South China), 2010, (10):71-75.
[2] Dang Q Hung, Olga Nekrassova, Richard G Compton. Analytical methods for inorganic arsenic in water: a review[J]. Talanta, 2004, 64: 269-277.
[3] Xiu-Ping Yan, Xue-Bo Yin, Xi-Wen He, et al . Flow injection on-line sorption preconcentration coupled with hydride generation atomic fluorescence spectrometry for determination of (ultra)trace amounts of arsenic(III) and arsenic(V) in natural water samples[J]. Analytical Chemistry, 2002, 74(9): 2162-2166.
[4] Zhongxi Li, Liping Zhou. Interferences removal for cadmium determination in samples with complex matrices by hydride generation coupled with non-dispersive atomic fluorescence spectrometry[J]. Analytical Sciences, 2006, 22(1): 123-126.