Determination of total oil in refined titanium tetrachloride by hydrolysis-infrared absorption spectroscopy
WANG Yanjiao1, ZOU Xiaonan2, ZU Yue3, SONG Guanglin*1
1. Guizhou Academy of Analysis and Testing,Guiyang 550016,China; 2. Guizhou Engineering Vocational College Scientific Bureau,Tongren 565200,China; 3. Guizhou Testing Technology Reserch and Application Center,Guiyang 550016,China
Abstract:The refined titanium tetrachloride is the key raw material to produce sponge titanium and titanium. The key to improve the quality of sponge titanium and titanium is to control the impurity content in refined titanium tetrachloride. Due to the production process, the carbon impurities in refined titanium tetrachloride are mainly oil impurities, so the determination of oil impurities in refined titanium tetrachloride is of great significance to the analysis of carbon impurities in refined titanium tetrachloride. The total oil is mainly composed of carbon which has infrared absorption band, so it can be determined by infrared absorption spectroscopy. However, titanium tetrachloride is easily hydrolyzed when contacting with water and air, and the generated hydrogen chloride also has infrared absorption peak. Moreover, the wave number of absorption peaks of hydrogen chloride and oils is close. As a result, hydrogen chloride interferes with the determination of total oil content in the original titanium tetrachloride sample by infrared absorption spectroscopy.A method for the determination of total oil content in refined titanium tetrachloride by hydrolysis-infrared absorption spectroscopy was established. The titanium tetrachloride sample was hydrolyzed using water with a volume ratio of 1∶25. After equilibrium, the total oil in the hydrolyzed solution was extracted by tetrachloroethylene. The content of total oil in refined titanium tetrachloride was quantitatively analyzed by external standard method. The linear range of total oil in calibration curve was 0-80 mg/L with correlation coefficient (r) of 0.999 9. The limit of detection of total oil was 2.5 mg/kg. The proposed method was applied for the determination of total oil in refined titanium tetrachloride sample. The relative standard deviations (RSD, n=6) of determination results were between 3.5% and 4.1%, and the spiked recoveries were between 96% and 109%.
王艳娇, 邹小南, 祖跃, 宋光林. 水解-红外吸收光谱法测定精四氯化钛中总油[J]. 冶金分析, 2022, 42(8): 76-80.
WANG Yanjiao, ZOU Xiaonan, ZU Yue, SONG Guanglin. Determination of total oil in refined titanium tetrachloride by hydrolysis-infrared absorption spectroscopy. , 2022, 42(8): 76-80.
[1] 陈文生,兰薇.红外半定量法测定精四氯化钛中氯化氢和二氯氧钛[J].贵州科学,1996(4):56-59. CHEN Wensheng,LAN Wei.Determination of the hyd-rochloride and titanium oxychloride content in titanium tetrachloride by means of infrared spectrometry semiquantitative method[J].Guizhou Science,1996(4):56-59. [2] 陈文生,兰薇.标准加入法定量测定四氯化钛中的三氯乙酰氯[J].贵州师范大学学报(自然科学版),2001,19(3):56-58. CHEN Wensheng,LAN Wei.Quantitaive determination for the trichloro-acetyl chloride in titanium tetrachloride by means of standard addition extrapolation[J].Journal of Guizhou Normal University (Natural Sciences),2001,19(3):56-58. [3] 宋光林,罗运军,李晋庆,等.一套红外池测定精四氯化钛中二氯氧钛的含量[J].光谱学与光谱分析,2015,35(12):3427-3430. SONG Guanglin,LUO Yunjun,LI Jinqing,et al.A set of infrared cells for the determination of titanium oxychloride in refined titanium tetrachloride[J].Spectroscopy and Spectral Analysis,2015,35(12):3427-3430. [4] 陈江韩,郭鹏然,陈智勇,等.精四氯化钛中痕量四氯化碳的分析[J].分析测试学报,2013,32(7):829-833. CHEN Jianghan,GUO Pengran,CHEN Zhiyong,et al.Determinationof carbon tetrachloride in refined titanium tatrachloride[J].Journal of Instrumental Analysis,2013,32(7):829-833. [5] 张芳,张立,王昊阳,等.顶空提取/气象色皮-四级杆质谱联用定量分析精TiCl4中痕量CS2与CCl4[J].分析测试学报,2013,32(12):1487-1491. ZHANG Fang,ZHANG Li,WANG Haoyang,et al.Quantitative analysis of trace levels of CS2 and CCl4 in refined TiCl4 using headspace extraction coupled with gas chromatography-quadrupole mass spectrometry[J].Journal of Instrumental Analysis,2013,32(12):1487-1491. [6] SONG Guanglin,LUO Yunjun,LI Jinqing,et al.Determination of carbon dioxide in refined titanium tetrachloride by infrared spectroscopy[J].Spectroscopy and Spectral Analysis,2015,35(3):626-630. [7] 宋光林,郭鹏然,李晋庆,等.酸水解-离子色谱法测定精四氯化钛中三氯乙酰氯[J].分析化学,2015,43(6):909-913. SONG Guanglin,GUO Pengran,LI Jinqing,et al.Determination of trichloroacetyl chloride in refine titanium tetrachloride by acid hydrolysis and ion chromatography[J].Chinese Journal of Analytical Chemistry,2015,43(6):909-913. [8] 生态环境部.HJ 637—2018 水质石油和动植物油类的测定 红外分光光度法[S].北京:中国环境出版社,2018. [9] 生态环境部.HJ 168—2020 环境监测分析方法标准制订技术导则[S].北京:中国环境出版社,2020.