Abstract:The fluoride, chloride, sulfide and low melting point metal ions on the surface of nuclear power equipment may cause the corrosion failure of material surface, which directly affects the service life and operation safety of nuclear reactor system. Therefore, it is very important to detect the contents of F-, Cl-, Pb2+ and SO2-4 on the surface of nuclear power equipment. In this paper, a new detection method, i.e., wipe test method, for the quantitative determination of F-, Cl-, Pb2+ and SO2-4 on the surface of nuclear power equipment was established. This method included three steps: sample collection, sample treatment and sample analysis. The gauze after treatment in boiling water was used to wipe the surface of nuclear power equipment. The wiping area of each gauze was usually 20 dm2. The wiped and unwiped gauze samples were put into beakers separately. After adding water, the beaker was heated to slight boiling at 90-100 ℃ for 30 min. Then the solution was filtrated with halide-free 0.45 μm filter paper, and the test sample and the contrast sample were obtained. The contents of F-, Cl- and SO2-4 were determined by ion chromatography (IC), while the content of Pb2+ was determined by graphite furnace atomic absorption spectrometry (GF-AAS). Consequently, the content of each ion in unit area could be calculated, realizing the accurate determination of F-, Cl-, Pb2+ and SO2-4 on the surface of nuclear power equipment. Under the optimized experimental conditions, the limit of detection of F-, Cl-, Pb2+ and SO2-4 in this method was 0.01 μg/mL, 0.02 μg/mL, 0.05 μg/mL and 0.001 μg/mL, respectively. The contents of F-, Cl-, Pb2+ and SO2-4 on the surface of stainless-steel welding layer were determined according to the experimental method, and the relative standard deviations (RSD, n=6) of the determination results were between 3.6% and 5.3%. The standard solution of four irons were added into the sample solution for standard recovery tests. The spiked recoveries were between 99% and 116%.
王楠, 魏占超, 冶金辉. 擦拭检验法在测定核电设备表面氟氯铅和硫酸根中的应用[J]. 冶金分析, 2024, 44(5): 25-30.
WANG Nan, WEI Zhanchao, YE Jinhui. Application of wipe test in determination of fluorine,chlorine,lead and sulfate on the surface of nuclear power equipment. , 2024, 44(5): 25-30.
[1] 王晓强,吕伟超,赵联瑞,等.在氯离子环境下不锈钢腐蚀原因分析和预防措施[J].安装(Installation),2019(9):38-40. [2] 张东玖,程从前,杨华,等.钝化膜完整性对不锈钢海洋大气腐蚀的影响及其质检方法[J].腐蚀与防护,2023,44(5):46-50,56. ZHANG Dongjiu,CHENG Congqian,YANG Hua,et al.Effect of passivation film integrity on marine atmospheric corrosion of stainless steel and its quality inspection methods[J].Corrosion & Protection,2023,44(5):46-50,56. [3] 熊静,邓平,高军,等.液态铅铋介质中奥氏体不锈钢腐蚀第一性原理研究[J].科学技术创新,2022(10):53-56. XIONG Jing,DENG Ping,GAO Jun,et al.First-principles study on corrosion of austenitic stainless steel in liquid lead-bismuth[J].Scientific and Technological Innovation,2022(10):53-56. [4] Subcommittee A01.14 on Methods of Corrosion Testing.ASTM A380-17 Standard practice for cleaning, descaling, and passivation of stainless steel parts, equipment, and systems[S].West Conshonocken:ASTM International,2017. [5] Subcommittee D19.02 on Quality Systems,Specification,and Statistics.ASTM D1193-06 Standard specification for reagent water[S].West Conshonocken:ASTM International,2006. [6] 国家市场监督管理总局,国家标准化管理委员会.GB/T 39305—2020再生水水质 氟、氯、亚硝酸根、硝酸根、硫酸根的测定 离子色谱法[S].北京:中国标准出版社,2020. [7] 邢文,邰春娇.硝酸钯基体改进剂-石墨炉原子吸收光谱法测定食盐中铅[J].中国卫生检验杂志,2012,22(4):723-724. XING Wen,TAI Chunjiao.Determination of trace lead in salt by GFAAS with palladium nitrate as matrix modifier[J].Chinese Journal of Health Laboratory Technology,2012,22(4):723-724. [8] 陈宁,于彦彬,刘嵘.离子色谱法测定氟化物的干扰及其消除[J].理化检验(化学分册),2000,36(2):70-71. CHEN Ning,YU Yanbin,LIU Rong.Elimination of the interference in the determinaion of fluoride by ion chromatography[J].Physical Testing and Chemical Analysis(Part B:Chemical Analysis),2000,36(2):70-71. [9] 国家质量监督检验检疫总局.JJG 823—2014离子色谱仪[S].北京:中国质检出版社,2014. [10] 国家质量监督检验检疫总局.JJG 694—2009原子吸收分光光度计[S].北京:中国计量出版社,2010.