Abstract:At present, the determination of fluorine content in copper concentrate usually adopts the national standard methods of GB/T 3884.5-2012 and GB/T 3884.12-2010. Although these two methods have high accuracy, they are both complicated and have high requirements for the operator. 0.50 g of sample was weighted, and 0.6 g of quartz sand, which was burned at 1 100 ℃ for 1 h, was added. At oxygen flow rate of 600 mL/min, the fluorine content was determined by automatic fluorine analyzer with dynamic slope. Thus, a method for determination of fluorine in copper concentrate was established by automatic fluorine analyzer. The relative standard deviations (RSD,n=11) of the determination results for fluorine in copper concentrate samples were all less than 5% when the fluorine contents were in the range of 0.014%-0.454% (mass fraction). The proposed methods were applied in determination of reference material or certified reference material of copper concentrate, and the determination results were consistent with the certified value or standard value. The fluorine contents in copper concentrate samples were determined according to the proposed method and the national standard methods, respectively. Moreover, the F-test and t-test were conducted. The results showed that there was no significant difference between the proposed method and the national standard methods.
[1] 袁从慧,阮毅,邹学权,等.氧瓶燃烧-离子色谱法测定铜精矿中氟[J].冶金分析,2016,36(8):30-34. YUAN Conghui,RUAN Yi,ZOU Xuequan,et al.Determination of fluoride in copper concentrate by oxygen flask combustion-ion chromatography[J].Metallurgical Analysis,2016,36(8):30-34. [2] 杨永丰.高氟铜精矿的处理[J].中国有色冶金,2010(5):32-34. YANG Yongfeng.Treatment of high fluorine copper concentrates [J].China Nonferrous Metallurcy,2010(5):32-34. [3] 李增强.煤中氟的离子选择性电极法测定方法研究[J].科技风,2013(17):140. LI Zengqiang.Determination of fluorine in coal by ion selective electrode method[J].Technology Wind,2013(17):140. [4] 夏传波,钱惠芬,田兴磊,等.地质样品中氯的测定方法的近期进展[J].理化检验(化学分册),2019,55(12):1466-1475. XIA Chuanbo,QIAN Huifen,TIAN Xinglei,et al.Recent advances of methods for determination of chlorine in geological samples[J].Physical Testing and Chemical Analysis(Part B:Chemical Analysis),2019,55(12):1466-1475. [5] 刘振德.煤中氟测定方法中高温燃烧水解过程影响因素分析[J].煤质技术,2016,31(6):39-41. LIU Zhende.Analysis of influencing factors of hight temperature combustion hydrolysis process in the determination of fluorine in coal[J].Coal Quality Technology,2016,31(6):39-41. [6] 彭炳先,吴代赫.高温热水解离子色谱法快速同时测定粘土中的卤素[J].分析化学,2013,41(10):1499-1504. PENG Bingxian,WU Daihe.Simultaneous determination of halogens in clay using pyrohydrolysis combined with ion chromatography[J].Chinese Journal of Analytical Chemistry,2013,41(10):1499-1504. [7] 王虹,魏秉炎,李异,等.自动快速燃烧-离子色谱法测定铜精矿中的氟[J].中国无机分析化学,2021,11(6):69-72. WANG Hong,WEI Bingyan,LI Yi,et al.Determination of fluoride in copper concentrate by ion chromatography with automatic quick furnace[J].Chinese Journal of Inorganic Analytical Chemistry,2021,11(6):69-72. [8] 时天昊,余蕾.碱熔-离子选择电极法测定植物样品中痕量氟[J].广东化工,2017,44(13):54-55. SHI Tianhao,YU Lei.Determination of trace fluorine in plant material by alkali melt-ion selective electrode method[J].Guangdong Chemical Industry,2017,44(13):54-55. [9] 黎香荣,黄园,赖天成.高温水解-离子色谱法测定有色金属矿中氟和氯[J].冶金分析,2018,38(2):53-58. LI Xiangrong,HUANG Yuan,LAI Tiancheng.Determination of fluoride and chloride in nonferrous metal ore by pyrohydrolysis-ion chromatography[J].Metallurgical Analysis,2018,38(2):53-58. [10] 刘晓川,罗彬彬,闫爱峰,等.采用动态斜率法准确测定煤中氟的实验对比研究[J].煤质技术,2020,35(6):71-74. LIU Xiaochuan,LUO Binbin,YAN Aifeng,et al.Experimental comparison research of accurate determination of fluorine in coal by dynamic slope method[J].Coal Quality Technology,2020,35(6):71-74. [11] 初奎明,王建,殷志源,等.采用动态斜率法加标测定煤中氟的回收率验证与比较[J].煤质技术,2022,37(3):91-96. CHU Kuiming,WANG Jian,YIN Zhiyuan,et al.Verification and comparison of determination of fluorine in coal by dynamic slope method with standard solution adding[J].Coal Quality Technology,2022,37(3):91-96. [12] 王化阳.离子选择电极法测定煤中氟影响因素研究[J].煤质技术,2016(3):28-33. WANG Huayang.Study on the factors for the determination of total fluorine in coal by fluoride-ion selective electrode method[J].Coal Quality Technology,2016(3):28-33.