Determination of gallium in cerium and cerium-rich sintered permanent magnet by inductively coupled plasma mass spectrometry
BAO Xiang-chun1,2, YU Yong-hai*1,2, HAO Qian1,2, GAO Li-hong1,2
1. State Key Laboratory of Baiyunobo Rare Earth Resource Researches and Comprehensive Utilization, Baotou Research Institute of Rare Earths, Baotou 014030, China; 2. Ruike National Engineering Research Center of Rare Earth Metallurgy and Function Materials, Baotou 014030, China
Abstract:The content of gallium in cerium and cerium-rich sintered permanent magnet can affect their magnetic properties. Therefore, the accurate determination of gallium content in cerium and cerium-rich sintered permanent magnet has great significance for their applications.The sample was dissolved with nitric acid (1+1)-hydrogen peroxide at low temperature. A method for the determination of gallium in cerium and cerium-rich sintered permanent magnet by inductively coupled plasma mass spectrometry (ICP-MS) was established using 2% (V/V) nitric acid as the determining medium. In consideration of double charge interference by main element (cerium) and impurity element (lanthanum) in the sample, 69Ga+ was selected as the determination isotope. Meanwhile, the double charge ion interference correction formula was used to further correct the mass spectral interference of 138La2+ (0.089%) and 138Ce2+ (0.25%) with the determination of 69Ga+. The matrix effect and signal shift of instrument were effectively corrected using 10.00ng/mL 103Rh as the internal standard. Experiments showed that the mass concentration of gallium and the ratio of the response value of gallium to rhodium had a good linear relationship. The linear correlation coefficient of gallium calibration curve was 0.99991. The limit of detection was 0.07ng/mL, and the limit of quantification was 0.23ng/mL. The content of gallium in cerium and cerium-rich sintered permanent magnets was determined according to the experimental method. When the mass fraction was 0.0181% and 0.0221%, the relative standard deviation (RSD, n=11) was 2.5% and 2.1%, respectively. The spiked recoveries were between 99% and 104%.
朱小龙.电感耦合等离子体发射光谱(ICP-OES)法测定钕铁硼磁体中铅含量[J].中国无机分析化学,2019,9(2):9-11.ZHU Xiao-long.Determination of lead in neodymium-iron-boron with ICP-OES[J].Chinese Journal of Inorganic Analytical Chemistry,2019,9(2):9-11.
[2]
杜梅,刘春,王东杰,等.电感耦合等离子体原子发射光谱法测定钕铁硼中钼钨铌锆钛[J].冶金分析,2014,34(3):65-68.DU Mei,LIU Chun,WANG Dong-jie,et al.Determination of molybdenum,tungsten,niobium,zirconium and titanium in NdFeB alloy by inductively coupled plasma atomic emission spectrometry[J].Metallurgical Analysis,2014,34(3):65-68.
[3]
黄豪杰,朱隽,许菲菲.火焰原子吸收光谱法测定钕铁硼磁铁中铅[J].冶金分析,2018,38(3):75-79.HUANG Hao-jie,ZHU Jun,XU Fei-fei.Determination of lead in neodymium-iron-boron magnetic alloy by flame atomic absorption spectrometry[J].Metallurgical Analysis,2018,38(3):75-79.
[4]
张立锋,张翼明,周凯红.电感耦合等离子体质谱法测定钕铁硼中铝、钴、铜、镓、锆、铽、钛、铌[J].冶金分析,2011,31(3):50-54.ZHANG Li-feng,ZHANG Yi-ming,ZHOU Kai-hong.Determination of aluminum,cobalt,copper,gallium,zirconium,terbium,titanium,niobium in neodymium iron boron by inductively coupled plasma mass spectrometry[J].Metallurgical Analysis,2011,31(3):50-54.
[5]
田旭玲,李勇,王浩.电弧熔炼制备标准样品-X射线荧光光谱法测定钕铁硼磁性材料成分[J].理化检验:化学分册,2015,51(9):902-906.TIAN Xu-ling,LI Yong,WANG Hao.Analysis of the composition of Nd-Fe-B magnetic material by XRF using arc-melting prepared reference materials[J].Physical Testing and Chemical Analysis Part B:Chemical Analysis,2015,51(9):902-906.
[6]
孙朝阳,董利明,贺颖婷,等.电感耦合等离子体质谱法测定地质样品中钪镓锗铟镉铊时的干扰及其消除方法[J].理化检验:化学分册,2016,52(9):1026-1030.SUN Chao-yang,DONG Li-ming,HE Ying-ting,et al.Elimination of interferences in ICP-MS determination of Sc,Ga,Ge,In,Cd and Tl in geological samples[J].Physical Testing and Chemical Analysis Part B:Chemical Analysis,2016,52(9):1026-1030.
[7]
程秀花,黎卫亮,王海蓉,等.封闭酸溶样ICP-MS法直接测定地质样品中镓、铟、铊、锗[J].分析试验室,2015,34(10):1204-1208.CHENG Xiu-hua,LI Wei-liang,WANG Hai-rong,et al.Determination of gallium,indium,thallium and germanium in geological samples after pressurized acid digestion by inductively coupled plasma mass spectrometry[J].Chinese Journal of Analysis Laboratory,2015,34(10):1204-1208.
[8]
李晓敬,边朋沙,金倩,等.高压微波消解-电感耦合等离子体质谱法测定地质样品中分散元素镓铟铊锗碲镉[J].冶金分析,2019,39(4):38-44.LI Xiao-jing,BIAN Peng-sha,JIN Qian,et al.Determination of disperse elements of gallium,indium,thallium,germanium,tellurium and cadmium in geological samples by inductively coupled plasma mass spectrometry with high-pressure microwave digestion[J].Metallurgical Analysis,2019,39(4):38-44.
[9]
唐碧玉,施意华,杨仲平,等.灰化酸溶-电感耦合等离子体质谱法测定煤炭中的镓锗铟[J].岩矿测试,2018,37(4):371-378.TANG Bi-yu,SHI Yi-hua,YANG Zhong-ping,et al.Determination of gallium,germanium and indium in coal by inductively coupled plasma-mass spectrometry with ashing acid digestion[J].Rock and Mineral Analysis,2018,37(4):371-378.
[10]
王佳翰,汤凯,向懋笔,等.密闭消解-电感耦合等离子体质谱法测定铅矿石中痕量镓铟铊镉锗[J].冶金分析,2018,38(12):19-25.WANG Jia-han,TANG Kai,XIANG Mao-bi,et al.Determination of trace gallium,indium,thallium,cadmium and germanium in lead ore by inductively coupled plasma-mass spectrometry with closed digestion[J].Metallurgical Analysis,2018,38(12):19-25.
[11]
董学林,何海洋.泡沫塑料吸附分离富集-电感耦合等离子体质谱法测定稀土矿石中的镓[J].岩矿测试,2016,35(1):42-47.DONG Xue-lin,HE Hai-yang.Determination of gallium in rare earth ore by inductively coupled plasma-mass spectrometry using polyurethane foam pre-concentration/separation[J].Rock and Mineral Analysis,2016,35(1):42-47.
[12]
黎卫亮,程秀花,张明祖,等.乙醇增强-电感耦合等离子体质谱法测定地质样品中镓铟铊锗碲[J].冶金分析,2014,34(3):13-18.LI Wei-liang,CHENG Xiu-hua,ZHANG Ming-zu,et al.Determination of gallium,indium,thallium,germanium and tellurium in geological samples by inductively coupled plasma-mass spectrometry with ethanol as a signal enhancer[J].Metallurgical Analysis,2014,34(3):13-18.