Abstract:Spark discharge atomic emission spectrometer has the characteristics of rapid analysis, accurate measurement and simultaneous determination of multiple elements. It is a commonly used analytical instrument for the production in iron and steel metallurgy industry, ultrapure metal analysis in nonferrous industry and special metal analysis in aviation industry. In particular, spark discharge atomic emission spectrometer is widely used in laboratories and ladle analysis in domestic iron and steel enterprises. An ARL4460 spark discharge atomic emission spectrometer, which has been used for nearly 20 years, was used as an example. Some fault phenomena, including abnormal vacuum degree, no intensity signal outputting of elements, absent of (-1 000V) negative high voltage being zero, and failure of on-line, were introduced. By systemically analyzing the structure principle of instrument and referencing technical data in maintenance, the reasons for faults were found out based on technical measurement. Moreover, the specific locations were determined. The faults were overcome by replacing spare parts and adjusting parameters to ensure the normal operation of instrument. The study provided good reference for the maintenance and repair of such equipment.
苑和锋,孙定煊,徐玲,等.直读光谱仪重要精密度指标的校准分析与评价[J].分析仪器2014(4):91-94.YUAN Hefeng,SUN Dingxuan,XU Ling,et al. Calibration analysis and evaluation for important precision parameters of direct-reading spectromete[J]. Analytical Instrumentation,2014(4):91-94.
[2]
刁正斌. ARL4460金属分析仪故障现象及其处理[J].重庆科技学院学报(自然科学版),2011,13(3):133-136.DIAO Zhengbin. Fault phenomenon and treatment of ARL4460 metal analyzer[J].Journal of Chongqing University of Science and Technology (Natural Science Edition), 2011,13(3):133-136
[3]
杨凤娟,刘珂,李静,等. 提高ARL4460直读光谱仪稳定性的探讨[J].分析仪器,2016 (1):91-93.YANG fengjuan,LIU Ke,LI Jing,et al.Discussion on improving the stability of ARL4460 direct reading spectrometer[J].Analytical Instruments,2016(1): 91-93
[4]
王明利,杨毅,刘晓光,等. ARL4460直读光谱仪电路板故障维修两例[J].分析仪器,2015 (5):92-95.WANG Mingli,YANG Yi,LIU Xiaoguang,et al.Two cases of troubleshooting for circuit board of ARL4460 direct reading spectrometer[J].Analytical Instrument,2015 (5): 92-95
[5]
李淼.ARL-4460型直读光谱仪典型故障的处理[J].本钢技术,2010(2):39-41.LI Miao.Treatment of typical faults of ARL-4460 direct reading spectrometer[J].Benxi Steel Technology,2010(2):39-41.
[6]