Determination of chromium and titanium in V-4Cr-4Ti alloy by inductively coupled plasma atomic emission spectrometry
CHENG Yong
Pangang Group Research Institute Co., Ltd., State Key Laboratory of Vanadium and Titanium Resources Comprehensive Utilization, Panzhihua 617000, China;
Abstract:The composition of vanadium-chromium-titanium alloy for nuclear reaction materials should be strictly controlled within the following proportion relationship: V-(3%-5%)Cr-(3%-5%)Ti. The content of alloying elements including chromium and titanium is usually determined one by one using titration method. The operation is complex and the analytical period is long. The determination of chromium and titanium in V-4Cr-4Ti alloy by inductively coupled plasma atomic emission spectrometry (ICP-AES) can meet the test requirements of chromium and titanium in vanadium-chromium-titanium alloy such as rapidness, high efficiency and simultaneous determination.The spectral interference and matrix effect between vanadium and chromium as well as titanium were emphatically studied in vanadium-chromium-titanium ternary alloy system. The spectral interference experiments and analysis of more than 20 major spectral lines of chromium and titanium were conducted. The analytical lines of chromium and titanium with appropriate sensitivity and no overlapping interference from the coexisting components were finally selected. The results showed that the matrix effect of vanadium and continuous background superimposition had a positive interference on the determination. The influence was eliminated by matrix matching and synchronous background correction. The proposed method optimized the working conditions of instrument and the detection conditions of analytical lines such as integral area and background correction area. The verification test indicated that the detection range of chromium and titanium was between 2.50% and 6.00%. The linear correlation coefficients of calibration curves were higher than 0.9992. The content of chromium and titanium in two V-4Cr-4Ti alloy samples was determined according to the experimental method. The relative standard deviations (RSD, n=8) of determination results were less than 0.70%. The spiked recoveries were between 98% and 102%. The proposed method was applied for the determination of chromium and titanium in four vanadium-chromium-titanium alloy samples, and the found results were consistent with those obtained by redox titration method according to standard method GB/T 4698.10-1996 and YS/T 514.1-2009.
李增德,崔舜,林晨光,等.聚变用V-Cr-Ti合金的研究现状与展望[J].稀有金属,2007,31(6):1-4.LI Zeng-de,CUI Shun,LIN Chen-guang,et al.Current research state and prospects of V-Cr-Ti alloys designing for fusion applications[J].Chinese Journal of Rare Metals,2007,31(6):1-4.
[2]
李鱼飞,罗超,王志钢,等.真空自耗电弧重熔V-4Cr-4Ti合金的微观组织结构[J].中国有色金属学报,2008,18(5):805-811.LI Yu-fei,LUO Chao,WANG Zhi-gang,et al.Microstructure of V-4Cr-4Ti alloy fabricated by vacuum are remeltion of consumable electrode[J].The Chinese Journal of Nonferrous Metals,2008,18(5):805-811.
[3]
李鱼飞,罗超,王志钢.VAR法制备钒合金的工艺探索[J].稀有金属,2007,31(Suppl):53-38.LI Yu-fei,LUO Chao,WANG Zhi-gang.Technology exploration of fabricate vanadium alloys by VAR[J].Chinese Journal of Rare Metals,2007,31(Suppl):53-38.
[4]
黎涛,冯自平,陈金发,等.电感耦合等离子体原子发射光谱法测定偏钒酸铵中钒含量[J].理化检验:化学分册,2011,47(9):1086-1087.LI Tao,FENG Zi-ping,CHEN Jin-fa,et al.ICP-AES determination of vanadium in ammonium metavana[J].Physical Testing and Chemical Analysis Part B:Chemical Analysis,2011,47(9):1086-1087.
[5]
杨新能,冯宗平,羊绍松.电感耦合等离子体原子发射光谱法测定钒铁合金中杂质元素[J].冶金分析,2014,34(11):37-41.YANG Xin-neng,FENG Zong-ping,YANG Shao-song.Determination of impurity elements in ferrovanadium ally by inductively coupled plasma atomic emission spectrometry[J].Metallurgical Analysis,2014,34(11):37-41.
[6]
成勇,敬守斌.电感耦合等离子体原子发射光谱法测定钒铝合金中15种杂质元素[J].理化检验:化学分册,2013,49(1):44-47.CHENG Yong,JING Shou-bin.ICP-AES determination of 15 impurity elements in V-Al alloy[J].Physical Testing and Chemical Analysis Part B:Chemical Analysis,2013,49(1):44-47.
[7]
周西林,王娇娜,刘迪,等.电感耦合等离子体原子发射光谱法在金属材料分析应用技术方面的进展[J].冶金分析,2017,37(1):39-46.ZHOU Xi-lin,WANG Jiao-na,LIU Di,et al.Inductively coupled plasma atomic emission spectrometry metal material application technology progress[J].Metallurgical Analysis,2017,37(1):39-46.
[8]
郑国经.电感耦合等离子体原子发射光谱分析仪器与方法的新进展[J].冶金分析,2014,34(11):1-10.ZHENG Guo-jing.New advances in inductively coupled plasma atomic emission spectrometries instruments and mtehods[J].Metallurgical Analysis,2014,34(11):1-10.
[9]
门生会.电感耦合等离子体原子发射光谱法测定硅铝钡锶合金中锶[J].冶金分析,2014,34(3):69-72.MEN Sheng-hui.Determiantion of strontium in silicon-aluminum-barium-stronium alloy by inductively coupled plasma atomic emission spectrometry[J].Metallurgical Analysis,2014,34(3):69-72.
[10]
谢卫华,刘勇,王怀胜.ICP-AES法测定U-Mo合金中钼含量[J].分析试验室,2016,35(4):448-450.XIE Wei-hua,LIU Yong,WANG Huai-sheng.Determination of molybdenum in U-Mo alloy by ICP-AES[J].Chinese Journal of Analysis Laboratory,2016,35(4):448-450.