Abstract:The instrumental parameters and analytical lines were optimized. The acidity for decomposition, the interference of matrix element and the internal standard element of acid-soluble boron were investigated. Consequently, the determination of acid-soluble boron in low alloy steel by inductively coupled plasma atomic emission spectrometry was treated. The results showed that, trace acid-soluble boron in low alloy steel could be determined under the following conditions: 249.677 nm was used as the analytical line for boron; the sample was dissolved using sulfuric acid (1+6); the beryllium and scandium mixed standard solution was used as double internal standard; the matrix matching of iron was used. The detection limit of method was 0.030 μg/mL. The relative standard deviation (RSD) was less than 10 %. The recoveries of standard addition were between 99 % and 101%.
Hara T, Asahi H. Role of combined addition of niobium and boron and of molybdenum and boron on hardnenability in low carbon steel [J]. ISU International,2004,44(8):1431-1440.
[2]
Tabuchi M. Improvement of creep strenght for Cr steel weldment boron addition[J]. Welding Research Abroad,2004,50(8-9):1-8.